Information Sheet

product specifications 369227f 02.19.14
4 Technical Support: 800.523.9466 (USA)
+44.(0)20.7702.0657 (Europe)
www.lutron.com
Operation
Wired and RF Configuration
RadioRA® 2 Repeaters
30 ft (9m)
maximum
30 ft (9m)
maximum
Main or Auxiliary Repeater
RF Link
60 ft (18 m)
maximum
Wired Link (Daisy-chain)
1000 ft (305m)maximum IEC PELV / NEC® Class 2 cable.
Two pairs:
one pair 18 AWG (1.0 mm
2
),
one pair 22 AWG to 18 AWG (0.5 mm
2
to 1.0 mm
2
) twisted
shielded.
Setup
Wired
RF
Communication
Repeater Status
1
3
4
2
M
Main Repeater
Power
Repeater Link
COM
9 V
1
N / C
MUX
MUX
2
3
4
Add
Test
Integrate
Program / Integrate
RS232
Ethernet
Setup
Wired
RF
Communication
Repeater Status
1
3
4
2
M
Add
Test
Repeater Status LEDs
Display the status of the Repeaters in
the system while in Test mode.
RF and Wired LEDs
Display the Tx / Rx activity on the RF
and wired links.
(Green = Tx; Orange = Rx)
Test and Add Buttons
Press and hold to enter the system
into Test mode or Add mode.
Test and Add LEDs
Flash green to indicate that the
system is in Test mode or Add mode.