Information Sheet
product specifications
02.10.20369225r
RadioRA 2 RF Maestro Local Controls
13
Customer Assistance:
1.844.LUTRON1 (U.S.A. / Canada)www.lutron.com/support
Wiring Diagrams
Continued on next page...
Wiring Diagram 1
Single-Location Installation without Neutral
1
-6CL, -10D, -PRO
Dimmer
Load
Brass
Black
Line / Hot
Green
Blue
1
Ground
Neutral
120 V~
50 / 60 Hz
Wiring Diagram 4
Single-Location 2-Wire Switch Installation
1
-8S-DV with Optional Shunt Capacitor
2
Switch
Load
Shunt
Capacitor
2
Brass
Black
Line / Hot
Green
Optional
Blue
1
Ground
Neutral
120 –277 V~
50 / 60 Hz
Wiring Diagram 2
Single-Location Installation with Neutral
1
-10ND, -6ND, -6NA, -2ANF, -8ANS, -PRO
Dimmer / Switch / Fan Speed Control
Load
Brass
Black
Silver
Line / Hot
Green
Blue
1
Ground
Neutral
120 V~
50 / 60 Hz
Wiring Diagram 3
Single-Location Fluorescent Dimmer Installation
1
-F6AN-DV with Lutron Ballast / LED Driver
Dimmer
Lutron
Ballast / LED
Driver
Lutron
Ballast / LED
Driver
Brass
Black
Silver
Line / Hot
Green
Orange
Orange
Orange
White
White
Black
Black
Blue
1
Ground
Neutral
120 –277 V~
50 / 60 Hz
Note: Bolded lines in diagrams indicate leads on products.
1
When using controls in single-location installations, tighten the blue terminal. Do not connect the blue terminal to any other wiring or
to ground.
2