Installation Manual
6
Lutron integration protocol
DEVICE Command-specific fields (continued)
Action Numbers and Parameters:
Action Action Number Parameters
Set (#) or Get (?) Zone Lock
1,2,3
15 0 = Off
1 = On
Set (#) or Get (?) Scene Lock
1,2,3
16 0 = Off
1 = On
Set (#) or Get (?) Sequence State
1,2,3
17 0 = Off
1 = Scenes 1– 4
2 = Scenes 5 –16
Set (#) Start Raising
3,4,5
18 None
Set (#) Start Lowering
3,4,5
19 None
Set (#) Stop Raising or Lowering
3,4,5
20 None
Get (?) battery status 22
1 = Normal, 2 = Low
Set (#) a custom lift and tilt level of venetian blinds
programmed to the phantom button
4,6
23 Lift level %
Tilt level %
Set (#) a custom lift level only of venetian blinds
programmed to the phantom button
4,6
24 Lift level %
Set (#) a custom tilt level only of venetian blinds
programmed to the phantom button
4,6
25 Tilt level %
Set (#) Hold or Release
2
32 None
Set (#) GRAFIK Eye QS Timeclock state 34
0 = Disabled
1 = Enabled
Get (?) Query CCI state
8
35 None
Set (#) or Get (?) Active LED Level
7
36 0 –100%
Set (#) or Get (?) Inactive LED Level
7
37 0 –100%
NOTES
1. Not supported in HomeWorks QS.
2. Not supported in RadioRA 2.
3. Not supported by Quantum.
4. Use OUTPUT command with equivalent action number in RadioRA 2.
5. Use OUTPUT command with equivalent action number in HomeWorks QS.
6. Use SHADEGRP command with equivalent action number in HomeWorks QS.
7. Applies only to Palladiom keypads.
8. Requires NWK firmware 8.47 or newer for QS Standalone systems.
Integrator’s Reference (continued)