Installation Manual

96
Lutron integration protocol
Scene 1
Scene 2
Scene 3
Palladiom Keypad (continued)
DEVICE Commands
DEVICE Command Formats
DEVICE Command-specific fields
Component Numbers:
Component Component Number Available Actions
Column 1, Button 1 1 Press, Release
Column 1, Button 2 2 Press, Release
Column 1, Button 3 3 Press, Release
Column 1, Button 4 4 Press, Release
Column 2, Button 1 5 Press, Release
Column 2, Button 2 6 Press, Release
Column 2, Button 3 7 Press, Release
Column 2, Button 4 8 Press, Release
Column 1, Lower 16 Press, Release
Column 1, Raise 17 Press, Release
Column 2, Lower 18 Press, Release
Column 2, Raise 19 Press, Release
Column 1, LED 1 81 Set or Get LED state
Column 1, LED 2 82 Set or Get LED state
Column 1, LED 3 83 Set or Get LED state
Column 1, LED 4 84 Set or Get LED state
Column 2, LED 1 85 Set or Get LED state
Column 2, LED 2 86 Set or Get LED state
Column 2, LED 3 87 Set or Get LED state
Column 2, LED 4 88 Set or Get LED state
Active LED Intensity
1
89 Set or Get LED state
Inactive LED Intensity
1
113 Set or Get LED state
NOTE
1. LED intensity can be set only when the DBM sensor is disabled.
Use “DEVICE Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
#DEVICE, 2, Component Number, Action Number, Parameters
Continued on next page…