Installation Manual

66
Lutron integration protocol
SHADEGRP Command Formats
SHADEGRP Command-specific fields
Action Numbers and Parameters:
Action Action Number Parameters
Set (#) or Get (?) Shade Group Level 1
Level
1
= 0 –100 or 0.00 –100.00
Delay
1
in: SS.ss
2
, SS, MM:SS, or HH:MM:SS
Set (#) Start Raising
3
2 None
Set (#) Start Lowering
3
3 None
Set (#) Stop Raising or Lowering 4 None
Set (#) or Get (?) Current Preset 6
Preset Number
4
= 0 30
Set (#) Tilt Level 14 Level
5
= 0 –100
6
or 0.00–100.00
6
Fade
1
in: SS.ss
2
, SS, MM:SS, or HH:MM:SS
Delay
1
in: SS.ss
2
, SS, MM:SS, or HH:MM:SS
Set (#) Lift and Tilt Levels 15
Lift
5
= 0 –100 or 0.00 –100.00
Tilt
5
= 0 –100
6
or 0.00–100.00
6
Fade
1
in: SS.ss
2
, SS, MM:SS, or HH:MM:SS
Delay
1
in: SS.ss
2
, SS, MM:SS, or HH:MM:SS
Set (#) Start Raising Tilt
3
16 None
Set (#) Start Lowering Tilt
3
17 None
Set (#) Stop Raising or Lowering Tilt
3
18 None
Set (#) Start Raising Lift
3
19 None
Set (#) Start Lowering Lift
3
20 None
Set (#) Stop Raising or Lowering Lift
3
21 None
Get (?) Horizontal Sheer Shade Region 28
Lift = 0
Tilt = 1
NOTES
1. The Fade and Delay time are optional. For shades, the Fade parameter has no effect (since shades have fixed speeds)
but it is required when specifying an optional delay. When not used, the system will use a zero-second delay. The
minimum fade and delay time is 0 seconds. The maximum fade and delay time is 4 hours.
2. Fractional seconds “SS.ss” will be rounded down to the nearest quarter second. For example, if a delay time is specified
as 1.45 seconds, a value of 1.25 seconds will be used.
3. When a Raise / Lower command is issued, the shade group’s level will continue to go towards open / close until a Stop
command is received.
4. Preset 0 is the Open Preset and Preset 30 is the Closed Preset.
5. The Level is accepted as a percentage, where 100% is fully open and 0% is fully closed.
6. 50 for Horizontal Sheer Blinds.
myRoom plus (continued)
System Commands (continued)
SHADEGRP Commands
Use “SHADEGRP Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
#SHADEGRP, 2, Action Number, Parameters
Continued on next page…
Assembled in U.S.A.
50015757 Rev. A