Installation Manual
71
Lutron integration protocol
ETHERNET Command-specific fields
Configuration Number and Parameters:
Description Configuration Number Parameters
Set (#) or Get (?) IP Address 0
IP Address (XXX.XXX.XXX.XXX)
Set (#) or Get (?) Gateway
Address
1 IP Address (XXX.XXX.XXX.XXX)
Set (#) or Get (?) Subnet Mask 2 IP Address (XXX.XXX.XXX.XXX)
Get (?) DHCP 4 None
Set (#) or Get (?) Multicast
Address
5
IP Address (XXX.XXX.XXX.XXX)
Example ETHERNET Commands
Operation Command String
Execute: #ETHERNET, Configuration Number, Parameters
Set IP Address to 192.168.250.1 #ETHERNET,0,192.168.250.1<CR><LF>
Set Gateway Address to 10.2.4.1 #ETHERNET,1,10.2.4.1<CR><LF>
Query: ?ETHERNET, Configuration Number, Parameters
What is the IP Address? ?ETHERNET,0<CR><LF>
Response: ~DEVICE, Integration ID, Configuration Number, Parameters
The IP Address is 192.168.250.1 ~ETHERNET,0=,192.168.250.1<CR><LF>
myRoom plus (continued)
System Commands (continued)
ETHERNET Commands
ETHERNET Command Formats
Use “ETHERNET Command-specific fields” tables
to complete these command fields.
Operation
Command
#ETHERNET, Configuration Number, Parameters
Assembled in U.S.A.