Installation Manual

111
Lutron® integration protocol
Hybrid Keypads: DEVICE Commands
Action Numbers and Parameters:
Action Action Number Parameters
Press 3 None
Release 4 None
Set (#) or Get (?) LED
State
NOTE: Set is for LEDs
on unprogrammed buttons only
9 0=Off
1=On
2=Normal-Flash: 1 flash every second
1
3=Rapid-Flash: 10 flashes every second
1
Example DEVICE Commands
Examples presume keypad has been assigned Integration ID 2.
Operation Command String
Execute: #DEVICE, Integration ID, Component Number, Action Number, Parameters
Press Button 1. #DEVICE,2,1,3<CR><LF>
Turn on LED 5. #DEVICE,2,85,9,1<CR><LF>
Query: ?DEVICE, Integration ID, Component Number, Action Number
What is the state of LED 1? ?DEVICE,2,81,9<CR><LF>
Response: ~DEVICE, Integration ID, Component Number, Action Number, Parameters
LED 1 is on. ~DEVICE,2,81,9,1<CR><LF>