Installation Manual
Table Of Contents
- Table of Contents
- About Integration
- Stanza
- QS Standalone
- RadioRA 2
- Quantum
- HomeWorks QS
- Devices
- Stanza Keypads
- Tabletop Stanza Keypads
- Stanza Dimmers
- Stanza Switch
- Stanza Lamp Module
- Stanza Input/Output Interface
- GRAFIK Eye QS
- Energi Savr Node QS/DALI
- Energi Savr Node QS/Int'l 0-10V
- Energi Savr Node QS/EcoSystem
- Energi Savr Node QS/0-10V
- seeTouch QS Keypads
- seeTouch QS Int'l Keypads
- Sivoia QS Shades
- Sivoia QS Venetian Blinds
- Maestro Dimmers
- Hybrid Keypad
- Tabletop seeTouch Keypads
- Pico Wireless Controls
- Visor Control Receiver
- Radio Powr Savr
- HVAC Controller
- Wireless Temperature Sensor
- Dynamic Keypad
- Programmers Appendix
- Contact Information
Visor Control Receiver
Learn
Visor Transmitter
Keypad
Outputs
Flash
Full
Security Input
Inputs
1 2
Power
9V
Inputs
C
Full
1 C 2 C
Outputs
3 C
4
C
Flash
121
Lutron® integration protocol
DEVICE Command-specific fields (continued)
•
Action Numbers and Parameters:
Action Action Number Parameters
Press, Close Input 3 None
Release, Open Input 4 None
Set (#) or Get (?) LED State
NOTE: Valid for Scene LEDs only
9 0=Off
1=On
Example DEVICE Commands
Examples presume Visor Control Reveiver has been assigned Integration ID 5.
Operation Command String
Execute: #DEVICE, Integration ID, Component Number, Action Number, Parameters
Press Scene 1. #DEVICE,5,1,3<CR><LF>
Turn on Scene 1 LED. #DEVICE,5,9,81,1<CR><LF>
Query: ?DEVICE, Integration ID, Component Number, Action Number
What is the state of LED 1? ?DEVICE,5,9,81<CR><LF>
Response: ~DEVICE, Integration ID, Component Number, Action Number, Parameters
LED 1 is on. ~DEVICE,5,9,81,1<CR><LF>
Visor Control Receiver:
DEVICE Commands
DEVICE Command Formats
Use “DEVICE Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
#DEVICE, 5, Component Number, Action Number, Parameters