Installation Manual
Table Of Contents
- Table of Contents
- About Integration
- Stanza
- QS Standalone
- RadioRA 2
- Quantum
- HomeWorks QS
- Devices
- Stanza Keypads
- Tabletop Stanza Keypads
- Stanza Dimmers
- Stanza Switch
- Stanza Lamp Module
- Stanza Input/Output Interface
- GRAFIK Eye QS
- Energi Savr Node QS/DALI
- Energi Savr Node QS/Int'l 0-10V
- Energi Savr Node QS/EcoSystem
- Energi Savr Node QS/0-10V
- seeTouch QS Keypads
- seeTouch QS Int'l Keypads
- Sivoia QS Shades
- Sivoia QS Venetian Blinds
- Maestro Dimmers
- Hybrid Keypad
- Tabletop seeTouch Keypads
- Pico Wireless Controls
- Visor Control Receiver
- Radio Powr Savr
- HVAC Controller
- Wireless Temperature Sensor
- Dynamic Keypad
- Programmers Appendix
- Contact Information
122
Lutron® integration protocol
Visor Control Receiver:
OUTPUT Commands
OUTPUT Command Format
#OUTPUT,21, 1, Parameters
OUTPUT Command-specific fields
Action Numbers and Parameters:
Action Action Number Parameters
Set (#) or Query (?) Output State 1 Level
1
= 0–100 or 0.00–100.00,
Set Pulse CCO (#) 6 Pulse
2
time in SS.ss
4
, MM:SS.ss
4
, or
HH:MM:SS.ss
4
, or
Delay
3
in SS.ss
4
, SS, MM:SS
4
, or
HH:MM:SS
4
Example OUTPUT Messages
Examples presume CCO has been assigned Integration ID 21.
Operation Command String
Set: #OUTPUT, Integration ID, Action Number, Parameters
Set output to open #OUTPUT,21,1,0<CR><LF>
Set output to close #OUTPUT,21,1,1<CR><LF>
Query
5
: ?OUTPUT, Integration ID, Action Number
What is the state of the output? ?OUTPUT,21,1<CR><LF>
Response
6
~OUTPUT, Integration ID, Action Number
Output state is closed ~OUTPUT,21,1,100.00<CR><LF>
NOTES
1. Any level greater than 0 will close the output. When level is equal to 0 the output will open.
2. The default time is one second.
3. The Fade and Delay time are optional. When not used the system will use a one second fade time
with zero second delay. The minimum fade and delay time is 0 seconds. The maximum fade and
delay time is 4 hours. For shade outputs, the Fade parameter has no effect (since shades have
fixed speeds) but it is required when specifying an optional delay.
4. Fractional seconds “SS.ss” will be rounded down to the nearest quarter second. For example, if a
fade time is specified as 1.45 seconds a value of 1.25 seconds will be used.
5. Momentary outputs should not be queried.
6. The system will report the target level of outputs. Any level greater than 0 means that the output is
closed.
Use “OUTPUT Command-specific fields” tables
to complete the parameter field.
Action number is always 1
for visor control outputs
Operation
Command
Integration ID (example)
Visor Control Receiver
Learn
Visor Transmitter
Keypad
Outputs
Flash
Full
Security Input
Inputs
1 2
Power
9V
Inputs
C
Full
1 C 2 C
Outputs
3 C
4
C
Flash