Installation Manual
Table Of Contents
- Table of Contents
- About Integration
- Stanza
- QS Standalone
- RadioRA 2
- Quantum
- HomeWorks QS
- Devices
- Stanza Keypads
- Tabletop Stanza Keypads
- Stanza Dimmers
- Stanza Switch
- Stanza Lamp Module
- Stanza Input/Output Interface
- GRAFIK Eye QS
- Energi Savr Node QS/DALI
- Energi Savr Node QS/Int'l 0-10V
- Energi Savr Node QS/EcoSystem
- Energi Savr Node QS/0-10V
- seeTouch QS Keypads
- seeTouch QS Int'l Keypads
- Sivoia QS Shades
- Sivoia QS Venetian Blinds
- Maestro Dimmers
- Hybrid Keypad
- Tabletop seeTouch Keypads
- Pico Wireless Controls
- Visor Control Receiver
- Radio Powr Savr
- HVAC Controller
- Wireless Temperature Sensor
- Dynamic Keypad
- Programmers Appendix
- Contact Information
128
Lutron® integration protocol
Wireless Temperature Sensor: DEVICE Commands
DEVICE Command Formats
DEVICE Command-specific fields
Component Number:
Component Component Number Available Actions
Battery Status 1 Get battery status
Action Numbers and Parameters:
Action Action Number Parameters
Get battery status 22 1 = Normal, 2 = Low
?DEVICE, 1, Component Number, Action Number, Parameters
Use “DEVICE Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
Example DEVICE Messages
Operation Command String
Query: ?DEVICE, Integration ID, Component Number, Action Number
What is the Temp. Sensor's Battery Status? ?DEVICE,1,1,22<CR><LF>
Response: ~DEVICE, Integration ID, Component Number, Action Number, Parameters
Temp. Sensor's Battery is Low. ~DEVICE,1,1,22,2<CR><LF>
Test