Installation Manual

17
Lutron® integration protocol
INTEGRATION ID Command Formats
INTEGRATION ID Command-specific fields
Actions
Description Action # Parameters
Set or Get Integration ID for a
Serial Number
1 Serial Number = 8 character HEX serial number of the
device, Integration ID = The integration ID to be assigned.
Change Integration ID 2 Current Integration ID, New Integration ID
NOTE: An error will be reported if the new
Integration ID is the same as an existing Integration ID in
the system.
Get Info from ID 3 Integration ID
NOTE: If this field is left blank, all integration IDs will be
printed.
Set or Get output Integration ID 4 Serial Number, Component Number, Integration ID
Example INTEGRATION ID Commands
Operation Command String
Execute: #INTEGRATIONID, Action Number, Parameters
Set the Integration ID for a serial number
#INTEGRATIONID,1,1234ABCD,kitchen dimmer
<CR><LF>
Response: ~INTEGRATIONID, Action Number, Parameters
Set the Integration ID for a serial number
~INTEGRATIONID,1,1234ABCD,kitchen dimmer
<CR><LF>
Execute: ?INTEGRATIONID, Action Number, Parameters
Get the Integration ID for a serial number
?INTEGRATIONID,1,5678EFEF
<CR><LF>
Response: ~INTEGRATIONID, Action Number, Parameters
Get the Integration ID for a serial number
~INTEGRATIONID,1,5678EFEF,living room keypad
<CR><LF>
Execute: #INTEGRATIONID, Action Number, Parameters
Change the Integration ID
#INTEGRATIONID,2,diningroomlights1,diningroomaccents
<CR><LF>
Response: ~INTEGRATIONID, Action Number, Parameters
Change the Integration ID
~INTEGRATIONID,2,diningroomlights1,diningroomaccents
<CR><LF>
Execute: ?INTEGRATIONID, Action Number, Parameters
Get information about an Integration ID
command
?INTEGRATIONID,3,livingroomkeypad
<CR><LF>
Response: ~INTEGRATIONID, Action Number, Parameters
Get information about an Integration ID
command
~INTEGRATIONID,3,livingroomkeypad,DEVICE,5678EFEF
<CR><LF>
Use “INTEGRATIONID Command-specific fields”
tables to complete these command fields.
Operation
Command
#INTEGRATIONID, Action Number, Parameters
QSE-CI-NWK-E: INTEGRATION ID Commands
Con/Act
FD/Col
DATA RX
DATA TX
RS232 RX
RS232 TX
LNK/ACT
PWR
1 2 3 4
1 2 3 4 5 6 7 8
QSE-CI-NWK-E
24 V 100 mA
800.523.9466
1.610.282.3800
www.lutron.com/qs
QS Link
QS Standalone System Commands (continued)