Installation Manual
Table Of Contents
- Table of Contents
- About Integration
- Stanza
- QS Standalone
- RadioRA 2
- Quantum
- HomeWorks QS
- Devices
- Stanza Keypads
- Tabletop Stanza Keypads
- Stanza Dimmers
- Stanza Switch
- Stanza Lamp Module
- Stanza Input/Output Interface
- GRAFIK Eye QS
- Energi Savr Node QS/DALI
- Energi Savr Node QS/Int'l 0-10V
- Energi Savr Node QS/EcoSystem
- Energi Savr Node QS/0-10V
- seeTouch QS Keypads
- seeTouch QS Int'l Keypads
- Sivoia QS Shades
- Sivoia QS Venetian Blinds
- Maestro Dimmers
- Hybrid Keypad
- Tabletop seeTouch Keypads
- Pico Wireless Controls
- Visor Control Receiver
- Radio Powr Savr
- HVAC Controller
- Wireless Temperature Sensor
- Dynamic Keypad
- Programmers Appendix
- Contact Information
27
Lutron® integration protocol
Connection Information
Provides an RS232 and Ethernet connection to communicate with external equipment.
RS232
The RS232 connection has the following communication settings:
•
Baud Rate 9600
•
8 data bits
•
No parity bit
•
1 stop bit
•
No flow control
Ethernet
Configuring the control interface to communicate over a network takes not only knowledge of
the RadioRA 2 system, but of networking as well. Installers with limited networking knowledge
are advised to contact a networking professional before attempting to connect a control interface
through a network. The information below will help an installer communicate the control interface
configurations to a network professional.
The installer will make any necessary changes to the control interface using the Lutron® DeviceIP or
RadioRA 2 PC software tool and the network professional can make any necessary changes to the
networking equipment.
Single Ethernet Port
•
IEEE® 802.3 Auto-Sensing 10BaseT / 100BaseTX
•
Supports MDI/MDIX auto-crossover (no crossover cable needed).
•
Female 8P8C “Computer RJ-45” socket
•
Green Connect LED, Amber Activity LED
•
Use Cat 5 cabling or better
TCP / IP Settings
•
DHCP (dynamic) or static configuration <factory default = DHCP>
•
IP Address: <static default = 192.168.1.50 or dynamic configuration>
•
Subnet Mask: < static default = 255.255.255.0 or dynamic configuration >
•
Gateway: <static default = 0.0.0.0 or dynamic configuration>
Protocols Used for Integration
•
TELNET
Telnet Server
•
Up to 4 telnet sessions can be accessed through Essentials Software
•
Used by software and/or third party equipment (i.e. touch screen)
•
Limited to transferring ASCII characters
•
Telnet Port number is 23, can be changed using the Lutron DeviceIP software or RadioRA 2 PC
software
•
Login: lutron
•
Password: integration
Notes: -Up to four additional login and password values can be defined in the RadioRA 2 PC Software.
-Only one connection per login/password is allowed at a time.
UDP Multicast Messaging
•
Used by the RadioRA 2 PC software during device configuration and system programming
•
There are no user modifiable settings for UDP messaging
Setup
Wired
RF
Communication
Repeater Status
1
3
4
2
M
Main Repeater
Power
Repeater Link
COM
9 V
1
N / C
MUX
MUX
2
3
4
AddTest
Integrate
Program / Integrate
RS232
Ethernet
USB
RadioRA® 2 Integration Access Points (continued)