Lutron® integration protocol
HQP6-2-120: MONITORING Commands
MONITORING Command Formats
MONITORING Command-specific fields
Monitoring Type:
Description Monitoring Type
Diagnostic Monitoring 1
Event Monitoring 2
Button Monitoring 3
LED State Monitoring 4
Zone Level Monitoring 5
Occupancy Monitoring 6
Area Scene, Device Scene and Shade Group Preset Number Monitoring 8
Time Clock Monitoring 9
Reply State
(if disabled, all messages FROM the integration access point will cease)
11
Prompt State (if disabled, the prompt will not be printed to the terminal) 12
Sequence Monitoring 16
HVAC Monitoring 17
Mode Monitoring 18
Action Numbers:
Action Action Number
Enable 1
Disable 2
Example MONITORING Messages
Operation Command String
Execute: #MONITORING, Monitoring Type, Action Number
Disable Diagnostic Monitoring. #MONITORING,1,2<CR><LF>
Enable Button Monitoring. #MONITORING,5,1<CR><LF>
Query: ?MONITORING, Monitoring Type
Is Button Monitoring enabled? ?MONITORING,3<CR><LF>
Response: ~MONITORING, Monitoring Type, Action Number
Button Monitoring is enabled. ~MONITORING,3,1<CR><LF>
Use “MONITORING Command-specific fields” tables
to complete these command fields.
Operation
Command
#MONITORING, Monitoring Type, Action Number
HomeWorks® QS System Commands (continued)