Installation Manual

9
Lutron® integration protocol
Stanza® Integration Access Points (continued)
Connection Information
Provides an RS232 and Ethernet connection to communicate with external equipment.
RS232
The RS232 connection has the following communication settings:
Baud Rate 9600
8 data bits
No parity bit
1 stop bit
No flow control
Ethernet
Configuring the control interface to communicate over a network takes not only knowledge of
the Stanza system, but of networking as well. Installers with limited networking knowledge are
advised to contact a networking professional before attempting to connect a control interface
through a network. The information below will help an installer communicate the control interface
configurations to a network professional.
The installer will make any necessary changes to the control interface using the Lutron® DeviceIP
or Stanza PC software tool and the network professional can make any necessary changes to the
networking equipment.
Single Ethernet Port
IEEE® 802.3 Auto-Sensing 10BaseT / 100BaseTX
Supports MDI/MDIX auto-crossover (no crossover cable needed).
Female 8P8C “Computer RJ-45” socket
Green Connect LED, Amber Activity LED
Use Cat 5 cabling or better
TCP / IP Settings
DHCP (dynamic) or static configuration <factory default = STATIC>
IP Address: <static default = 192.168.1.50 or dynamic configuration>
Subnet Mask: < static default = 255.255.255.0 or dynamic configuration >
Gateway: <static default = 0.0.0.0 or dynamic configuration>
NetBIOS Name: <factory default = LUTRON>
NetBIOS Name is case sensitive
Protocols Used for Integration
TELNET
Telnet Server
Used by software and/or third party equipment (i.e. touch screen)
Limited to transferring ASCII characters
Telnet Port number is 23, can be changed using the Lutron DeviceIP software
Login: lutron
Password: integration
UDP Multicast Messaging
Used by the Stanza PC software during device configuration and system programming
There are no user modifiable settings for UDP messaging