Installation Manual
97
Lutron integration protocol
Devices (continued)
Palladiom Keypad (continued)
DEVICECommands(continued)
DEVICE Command-specific fields (continued)
Action Numbers and Parameters:
Action Action Number Parameters
Set(#)Press 3 None
Set(#)Release 4 None
Set(#)Hold 5 None
Set(#)Double-tap 6 None
Set(#)orGet(?)LEDState
1
9 0 = O f f
1 = O n
2=Normal-Flash:1asheverysecond
1
3=Rapid-Flash:10asheseverysecond
1
Set(#)orGet(?)ActiveLED
Level
1,2
36 0–100
Set(#)orGet(?)InactiveLED
Level
1,2
37 0–100
NOTES
1 “Set”isforunprogrammedbuttonsandbuttonswithLEDlogic‘DenedbyIntegration ’
2 LEDintensitycanbesetonlywhentheDBMsensorisdisabled
Example DEVICE Commands
ExamplespresumekeypadhasbeenassignedIntegrationID2
Operation Command String
Execute: #DEVICE,IntegrationID,ComponentNumber,ActionNumber,Parameters
SetActiveLEDto50 #DEVICE,2,89,36,50<CR><LF>
Query: ?DEVICE,IntegrationID,ComponentNumber,ActionNumber
WhatistheInactiveLEDLevel? ?DEVICE,2,113,37<CR><LF>
Response: ~DEVICE,IntegrationID,ComponentNumber,ActionNumber,Parameters
InactiveLEDLevelis75% ~DEVICE,2,113,37,75<CR><LF>
Scene 1
Scene 2
Scene 3
Continuedonnextpage…