Installation Manual

125
Lutron integration protocol
Devices (continued)
Sivoia QS Shade / Sivoia QS Wireless Shade (continued)
OUTPUTCommands
OUTPUT Command Format
OUTPUT Command-specific fields
Action NumbersandParameters:
Action Action Number Parameters
Set(#)orGet(?)ZoneLevel 1 Level
1
=0–100or0 00 –100 00
2
Fade
3
in:SS ss
4
,SS,MM:SS,orHH:MM:SS
Delay
5
in:SS ss
4
,SS,MM:SS,orHH:MM:SS
Set(#)StartRaising 2 None
Set(#)StartLowering 3 None
Set(#)
StopRaisingor
Lowering
4 None
NOTES
1  Forshades,alevelof0(or0 00)equalsclosed,andalevelof100(or100 00)equalsfullopen
2  0%=Closed;100%=Open
3  Fadeisnotavailableforshadessincetheymoveataconstantrate Theparametermustbeenteredbutisignored
4  Fractionalseconds“SS ss”willberoundeddowntothenearestquartersecond Forexample,ifadelaytimeisspecied
as1 45secondsavalueof1 25secondswillbeused
5  TheDelaytimeisoptional Whennotused,thesystemwilluseazero-seconddelay Theminimumdelaytimeis
0 25seconds Themaximumdelaytimeis4hours Not supported in QS Standalone.
Example OUTPUT Messages
ExamplespresumeshadehasbeenassignedIntegrationID1
Operation Command String
Execute: #OUTPUT,IntegrationID,ActionNumber,Parameters
Setshadeto75%witha1min30secdelay #OUTPUT,1,1,75,0,1:30<CR><LF>
StartRaisingshadelevel #OUTPUT,1,2<CR><LF>
StopRaising/Loweringshadelevel #OUTPUT,1,4<CR><LF>
Query: ?OUTPUT,IntegrationID,ActionNumber
Whatisthestateoftheoutput? ?OUTPUT,1,1<CR><LF>
Response
1
: ~OUTPUT,IntegrationID,ActionNumber,Parameters
Outputlevelissetto90% ~OUTPUT,1,1,90.00<CR><LF>
NOTE
1  Thesystemwillreportthetargetlevelofashade Theactuallevelisnottransmittedwhiletheyaremoving 
Example:IftheLivingRoomBlackouts(IntegrationID1)areat20%andarecommandedtogoto100%bysending
#OUTPUT,1,1,100,theresponsefromthesystemwillbe~OUTPUT,1,1,100.00
Use “OUTPUT Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
#OUTPUT,1,ActionNumber,Parameters
Continuedonnextpage…