Installation Manual
128
Lutron integration protocol
Devices (continued)
Sivoia QS Venetian Blind / Sivoia QS Wireless Venetian Blind
(continued)
OUTPUTCommands
OUTPUT Command Format
OUTPUT Command-specific fields
Action NumbersandParameters:
Action Action Number Parameters
Set(#)orGet(?)LiftLevel 1 LiftLevel
1
=0–100or0 00 –100 00
Fade
2
in:SS ss
3
,SS,MM:SS,orHH:MM:SS
Delay
4
in:SS ss
3
,SS,MM:SS,orHH:MM:SS
Set(#)orGet(?)TiltLevel 9 TiltLevel
1
=0–100or0 00 –100 00
Fade
2
in:SS ss
3
,SS,MM:SS,orHH:MM:SS
Delay
4
in:SS ss
3
,SS,MM:SS,orHH:MM:SS
Set(#)orGet(?)LiftandTiltLevels 10 LiftLevel
1
=0–100or0 00 –100 00
TiltLevel
1
=0–100or0 00 –100 00
Fade
2
in:SS ss
3
,SS,MM:SS,orHH:MM:SS
Delay
4
in:SS ss
3
,SS,MM:SS,orHH:MM:SS
Set(#)StartRaisingTilt 11 None
Set(#)StartLoweringTilt 12 None
Set(#)StopRaisingorLoweringTilt 13 None
Set(#)StartRaisingLift 14 None
Set(#)StartLoweringLift 15 None
Set(#)StopRaisingorLowering
Lift
16 None
NOTES
1
2
Fadeisnotavailableforblindssincetheymoveataconstantrate Theparametermustbeenteredbutisignored
3 Fractionalseconds“SS ss”willberoundeddowntothenearestquartersecond Forexample,ifadelaytimeisspecied
as1 45seconds,avalueof1 25secondswillbeused
4 TheDelaytimeisoptional Whennotused,thesystemwilluseazero-seconddelay Theminimumdelaytimeis
0 25seconds Themaximumdelaytimeis4hours Not supported in QS Standalone.
Use “OUTPUT Command-specific fields” tables
to complete these command fields.
Operation
Command
Integration ID (example)
#OUTPUT,1,ActionNumber,Parameters
100% 75% 50% 25% 0%
Lift
Tilt
Continuedonnextpage…