Designer wallplate opening Skylark dimmers and fan controls ® 2.94 in (75 mm) Product family features Rocker switch returns light to your favorite light level • Slide up to brighten, down to dim (adjust light to suit any activity) • eco-dim® model available • 1000 W preset dimmers have voltage compensation which maintains stable light levels, despite line voltage variations • 4.
Designer wallplate opening Skylark dimmers and fan controls ® Available finishes Use BOLD color code in model number (Example: S-600P-GR) Gloss finishes* WH White LA Light Almond AL Almond GR Gray BR Brown BL Black IV Ivory SS Stainless Steel *Coordinating wallplates only available separately. For wallplate information, see pg. 160. Stainless Steel wallplate includes black plastic trim/adapter, visible from side. Match with separate Black (BL) controls. www.lutron.com | 1.800.523.
Designer wallplate opening Skylark dimmers and fan controls ® Dimmers Slide-to-off dimmers Slide up to on/brighten; down to dim/off • Dimmers with on/off switch and locator light Rocker switch turns on/off • Slide up to brighten; down to dim • • Includes amber locator light Dimmers with on/off switch Rocker switch turns on/off • Slide up to brighten; down to dim • eco-dim® model guarantees at least 15% energy savings compared to a standard switch • www.lutron.com | 1.800.523.
Designer wallplate opening Skylark dimmers and fan controls ® Fan and fan/light controls Dual devices Slide-to-off fan controls Dual slide-to-off dimmers (two loads) Slide up to on/increase speed; down to decrease/off Dimmers (left/right) • Slide up to on/brighten; down to dim/off • 3-quiet fan speeds for increased comfort • For use with only one ceiling paddle fan • Quiet 3-speed designed to prevent motor hum • Fully variable model also available • Slide-to-off fan controls w
Designer wallplate opening Skylark dimmers and fan controls ® Connections overview Load connections* Incandescent/ Halogen eco-dim® Incandescent/ Dimmer Halogen Dimmer Magnetic Low-Voltage Electronic Low-Voltage MLV Transformer (by others) ELV Transformer (by others) MLV Dimmer ELV Dimmer Fluorescent Lighting Dimmable CFL Lutron ® Dimming Ballasts Fluorescent Dimmer LED Ceiling Fan Ceiling Fan/Light Lutron Hi-lume ® LED Driver Fluorescent Dimmer Fluorescent Dimmer (3-wire only) Fan Cont
Designer wallplate opening Skylark dimmers and fan controls ® Dimmer model numbers Incandescent/halogen dimmers Magnetic low-voltage dimmers Dimmers with on/off switch Dimmers with on/off switch Single-pole 120 V 600 W Single-pole 120 V 1000 W S-600P-CC3 Single-pole 120 V 600 VA (450 W) SLV-600P-CC3 S-10P-CC3 3-way 120 V 600 VA (450 W) SLV-603P-CC3 3-way 120 V 600 W 3-way 120 V 1000 W S-603P-CC3 S-103P-CC3 eco-dim® dimmer with on/off switch 3-way/single-pole 120 V 600 W S-603PG-EE2 eco-dim
Designer wallplate opening Skylark dimmers and fan controls ® Dimmer model numbers 3-wire fl uorescent dimmers* Tu-Wire® fluorescent dimmers Dimmers with on/off switch Dimmers with on/off switch Single-pole 120 V 8 A Single-pole 277 V 6 A 3-way 120 V 8 A 3-way 277 V 6 A SF-10P-CC3 SF-12P-277-CC3 SF-103P-CC3 SF-12P-277-3-CC3 3-way/single-pole 120 V 5 A SFTU-5A3P-CC3 Also compatible with Advance Mark X ballasts, for further information, visit www.lutron.com/advance.
Designer wallplate opening Skylark dimmers and fan controls ® Fan control model numbers Fan controls Slide-to-off fan controls—quiet 3-speed Single-pole 120 V 1.5 A Single-pole 120 V 2.0 A SFSQ-F-CC3 SFSQ-F-HO-CC3 Single-pole fan control S2-LFSQ-CC3 120 V 1.5 A (left) 120 V single-pole dimmer 300 W (right) For use with only one ceiling paddle fan. For use with only one ceiling paddle fan. SFSQ-F-HO- for use with Hunter Original Series.
Designer wallplate opening Skylark dimmers and fan controls ® Dual device model numbers Replacement knob model numbers I ncandescent/halogen and Incandescent/halogen dimmers Dual slide-to-off dimmers (two loads) Knobs Single-pole 120 V 300 W light (left) incandescent/halogen 120 V 300 W light (right) incandescent/halogen S2-L-CC3 CC3: Gloss color codes, see pg. 105 (Wallplates not included, order separately, see pg.
Designer wallplate opening Skylark dimmers and fan controls ® Accessories Wallplates 4.75 in (121 mm) Shown actual size: 2-gang Claro® wallplate in White (WH). For more information about Designer wallplates, see pg. 160. 4.69 in (119 mm) .30 in (7.6 mm) profile Coordinated electrical devices For more information about coordinated Designer electrical devices, see pg. 163. Tamper resistant GFCI receptacle Customizable 6-port frame www.lutron.com | 1.800.523.
Wallplates and accessories | Designer | Claro /Satin Colors ® ® 4.75 in (121 mm) Shown actual size: Maestro dimmers and 2-gang Claro wallplate in White (WH). 4.69 in (119 mm) .30 in (7.
Wallplates and accessories | Designer | Claro /Satin Colors ® ® Available finishes Use BOLD color code in model number (Example: SC-1-PL) Gloss finishes LA Light Almond AL Almond IV Ivory GR Gray BR Brown BL Black SW Snow LS Limestone BI Biscuit ES Eggshell PD Palladium TP Taupe ST Stone BG Bluestone PL Plum SG Sea Glass TQ Turquoise GS Goldstone DS Desert Stone GB Greenbriar MS Mocha Stone TC Terracotta SI Sienna HT Hot MR Merlot MN Midnight WH White Satin finishes SS Stainles
Wallplates and accessories | Designer | Claro /Satin Colors ® ® Wallplates for Maestro®, Maestro IR®, Maestro Wireless®, PicoTM wireless control, Spacer System®, Diva®, Lyneo® Lx, Skylark® and Skylark ContourTM 1-gang* CW-1-CC2 SC-1-CC4 CW-4-CC2 SC-4-CC4 W: 8.37 in (213 mm); H: 4.69 in (119 mm); D: .30 in (7.6 mm) W: 2.94 in (75 mm); H: 4.69 in (119 mm) D: .30 in (7.6 mm) 2-gang* 4-gang* CW-2-CC2 SC-2-CC4 5-gang* CW-5-CC2 SC-5-CC4 W: 10.18 in (259 mm); H: 4.69 in (119 mm); D: .30 in (7.
Wallplates and accessories | Designer | Claro /Satin Colors ® ® Receptacles 6-gang* CW-6-CC2 SC-6-CC4 W: 12.00 in (305 mm); H: 4.69 in (119 mm); D: .30 in (7.
Wallplates and accessories | Designer | Claro /Satin Colors ® Receptacles for dimming use Receptacles for dimming use Duplex for dimming both connected loads Duplex for dimming both connected loads • • Projecting nubs prevent standard plugs from being used • Projecting nubs prevent standard plugs from being used • Requires replacement plugs for dimming use Requires replacement plugs for dimming use • • 15 A model shown Duplex for dimming use • 15 A 15 A 120/125 V* 120/125 V* CA
Wallplates and accessories | Designer | Claro /Satin Colors ® ® Replacement plug for dimming (use with receptacles on left) This plug required for use with Lutron® receptacles for dimming use—plug will work in standard receptacle • Easily replaces the existing plugs on lamps • 120/125 V White RP-FDU-10-WH 120/125 V Brown RP-FDU-10-BR UL/CSA/NOM regulatory approvals.
Wallplates and accessories | Designer | Claro /Satin Colors ® Field customizable 6-port frame • • • • ® Switches Shipped with six blanks in matching colors • Paddle turns on/off • Use with any 15 A load Connectors and wallplate sold separately • Connectors snap in (no tools required) • No derating if ganged Connectors available in White (WH), unless noted 6-port frame* CA-6PF-CC3 SC-6PF-CC4 Connectors for 6-port frame Telephone/network jacks 8-conductor, RJ45 category 3 CON-1P-C3-EE
Appendix | Multi-ganging derating Appendix | Ganging andand derating How to understand ganging and derating Standard ganging Ganging is the side-by-side mounting of two or more dimmers or accessory devices under a multi-gang wallplate. Standard multi-gang installation: • Uses standard multi-gang electrical backboxes • Uses standard multi-gang wallplates • • Requires fins to be removed from dimmers for proper spacing (“Fins Broken” ganging) May require derating (i.e.
Appendix | Ganging and derating Standard ganging and fins broken derating examples: = + No fins broken Full capacity One Nova Tb® dimmer = Standard 1-gang backbox + = Three Nova Tb dimmers “Fins Broken” ganging Standard 1-gang architectural wallplate + Standard 2-gang backbox One fin broken* Partial derating Two Nova Tb dimmers “Fins Broken” ganging + + Standard 2-gang architectural wallplate + Standard 3-gang backbox Inside: Two fins broken* Full derating Standard 3-gang architectural
Appendix | Multi-ganging derating Appendix | Ganging andand derating Derating Table 1 New Architectural | Vierti® Designer | Maestro®, Maestro IR®, Maestro Wireless®, Spacer System®, Diva®, Lyneo® Lx, Skylark ContourTM, Skylark® Traditional | Abella®, Ceana®, Ariadni®, Glyder®, Rotary No fins broken 1 fin broken 2 fins broken 600 W 500 W 400 W 1000 W 800 W 650 W 300 W 250 W 200 W 300 W 250 W 200 W 600 VA / 450 W 500 VA / 400 W 400 VA / 300 W 1000 VA / 800 W 800 VA / 650 W 650 VA /
Appendix and derating Appendix| |Multi-ganging Ganging and derating Derating Table 2 Architectural | Vareo®, Nova Tb® No fins broken 1 fin broken 2 fins broken 600 W 500 W 300 W 1000 W 900 W 700 W 1500 W 1250 W 1000 W 1950 W – – 600 VA / 450 W 500 VA / 400 W 300 VA / 250 W 1000 VA / 800 W 900 VA / 750 W 700 VA / 500 W 1500 VA / 1200 W 1250 VA / 1000 W 1000 VA / 800 W 300 W 300 W 250 W 600 W 500 W 400 W 20 ballasts / 8 A 20 ballasts / 6 A 20 ballasts / 4.
Appendix | Lighting load interfaces Dimmer capabilities and interface requirements ulti-location—true dimming from each location M eco-model available E Compatible dimmer (no interface) WBX TVI 3F PA Requires interface, see notes below M Dimmers Vierti®* pg. 14 capacity† Incandescent/halogen 120 V Magnetic low-voltage 120 V Vareo® pg. 20 Nova Tb® Nova® pg. 34 pg. 26 Centurion® pg.
Appendix | Lighting load interfaces Dimmer capabilities and interface requirements ulti-location—true dimming from each location M eco-model available E Compatible dimmer (no interface) WBX TVI 3F PA Requires interface, see notes below M Dimmers Maestro® Maestro Maestro Spacer pg. 46 IR® pg. 60 Wireless® System® pg. 68 pg. 76 capacity† M 600 W E Incandescent/halogen 120 V M M Diva® pg.
Appendix | Lighting load interfaces Dimmer capabilities and interface requirements ulti-location—true dimming from each location M eco-model available E Compatible dimmer (no interface) WBX TVI 3F PA Requires interface, see notes below M Dimmers Lyneo® Lx Skylark pg. 94 ContourTM pg.100 Skylark® pg. 104 Abella® pg.
Appendix | Lighting load interfaces Dimmer capabilities and interface requirements ulti-location—true dimming from each location M eco-model available E Compatible dimmer (no interface) WBX TVI 3F PA Requires interface, see notes below M Dimmers Ceana® pg. 120 Ariadni® pg. 124 Glyder® pg. 130 Rotary pg.
Appendix | Lighting load interfaces Dimmer models/load interface compatibility Incandescent, magnetic and electronic low-voltage (120/277 V) 3-wire Fluorescent ballasts or Hi-lume® LED drivers (120/277 V) 0-10 VDC Ballasts or LED drivers (120/277 V) WBX 3F TVI Wallbox Phase Adaptive Power Module* Fluorescent Power Module* 0-10 V Interface PHPM-WBX-DV-WH PHPM-3F-DV-WH GRX-TVI Dimmer Family Singlepole 3-way or multi-location Singlepole 3-way or multi-location Singlepole 3-way or multi-locat
Appendix | Lighting load interfaces Dimmer models/load interface compatibility Tu-Wire® Fluorescent Ballasts (120 V) Switched Lighting (120/277 V) PA SW Phase Adaptive Power Module* Switching Power Module* PHPM-PA-DV-WH PHPM-SW-DV-WH Dimmer Family Singlepole 3-way or multi-location Singlepole 3-way or multi-location Abella® – – – AB-S6AM- Ariadni® – AYF-103P- – – Ceana® – – – – – DVF-103P- – – – DVSCF-103P- – – Glyder® – – – – Lyneo® Lx – LXF-103PL- LX-1PSL- LX-
Addendum | Advanced conceptual connections Skylark Contour TM Incandescent dimming CFL/LED dimming Incandescent/ Halogen Screw-base CFL/LED Incandescent/ Halogen eco-dim® Dimmer C•LTM Dimmer C •L Dimmer For illustration purposes only. Consult model number pages for specific voltage and capacity information. www.lutron.com | 1.800.523.