DERATING/MAXIMUM CAPACITY
No side One side Two side
sections section sections
removed removed removed
(Full Capacity) (End Units) (Middle Unit)
Incandescent Dimmers
600 W 500 W 400 W
1000 W 800 W 650 W
Electronic Low-Voltage
300 W 250 W 200 W
Magnetic Low-Voltage
600 VA 500 VA 400 VA
(450 W
1
) (375 W
1
) (300 W
1
)
1000 VA 800 VA 650 VA
(800 W
1
) (650 W
1
) (500 W
1
)
Fluorescent
Hi-lume/Eco-10
20 ballasts/ 8 A No derating required
(ECO-Series)
Tu-Wire
2
5 A 4 A 3.3 A
Fan-Speed Controls
1.5 A
No derating required
1 Actual lamp wattage.
2 Minimum capacity: 2 ballasts/0.25 A
# ledoMnoitpircseD
STANDARD WALLPLATES
1-Gang
2.94 in (75 mm) W x 4.69 in (119 mm) H x
0.30 in (7.6 mm) D
CW-1-
2-Gang
4.75 in (121 mm) W x 4.69 in (119 mm) H x
0.30 in (7.6 mm) D
CW-2-
3-Gang
6.56 in (167 mm) W x 4.69 in (119 mm) H x
0.30 in (7.6 mm) D
CW-3-
4-Gang
8.37 in (213 mm) W x 4.69 in (119 mm) H x
0.30 in (7.6 mm) D CW-4-
5-Gang
10.18 in (259 mm) W x 4.69 in (119 mm) H x
0.30 in (7.6 mm) D CW-5-
6-Gang
12.00 in (305 mm) W x 4.69in (119 mm) H x
0.30 in (7.6 mm) D
CW-6-
STANDARD COLORS/FINISHES
Gloss Finishes
Add color/finish suffix to model number to order.
Example: DV-600P-WH
WH White
IV Ivory
AL Almond
LA Light Almond
GR Gray
BR Brown
BL Black
Controls
3691038c
Have questions or want to place an order?
Call Lutron Customer Assistance 1.844.LUTRON1 (588.7661)
MINIMUM LOAD REQUIREMENTS
Incandescent/Magnetic Low-Voltage
40 W
Electronic Low-Voltage
5 W
Fan-Speed Controls
.33 A
(40 W)
Fluorescent
Hi-lume/Eco-10
1 ballast
(ECO-Series)
Tu-Wire
3
2 ballasts