Installation Guide

Dimmer
For the Compatible Bulb Tool...
Helpful videos...
Advanced programming & operation...
Additional wiring scenarios...
Replacing a dimmer with a dimmer...
If using LED or CFL bulbs, they
must be Lutron compatible!
Use www.lutron.com/ledfinder
to check compatibility.
P/N 0301930
Rev. A
Sunnata touch dimmer
LED+ technology
LFCA
CFL
AFC
150 W
LED / LFCA
600 W
Incand. /Hal.
Help
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/
369-119_Wallbox_Warranty.pdf
©2019 Lutron Electronics Co., Inc.
)Lutron, Lutron, Claro, LED+, and Sunnata are trademarks or
registered trademarks of Lutron Electronics Co., Inc., in the U.S.
and/or other countries.
www.lutron.com/SunnataSupport
www.lutron.com/SunnataSupport
IMPORTANT
1. CAUTION: Use only with permanently installed fixtures with dimmable
screw-in LED, dimmable screw-in compact fluorescent, halogen, or
incandescent lamps. To avoid overheating and possible damage to other
equipment, do not use to control receptacles, motor-driven appliances,
or low-voltage transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. When no “grounding means” exists in wallbox, the 2011 National
Electrical CodeR (NECR) allows a control to be installed as a replacement
if 1) a nonmetallic, noncombustible faceplate is used with non-metallic
attachment screws or 2) the circuit is protected by a ground fault circuit
interrupter (GFCI). When installing a control according to these methods,
cap or remove green wire before screwing control into wallbox and use
an appropriate faceplate such as Claro series wallplates by Lutron.
4. 3-way wiring must use only one Sunnata Dimmer and an existing
mechanical switch. Re-wiring the mechanical switch is required. Product
is not compatible with 4-way wiring.
5. Never connect more than one dimmer to a load.
6. For indoor use only between 32 °F and 104 °F (0 °C and 40 °C).
7. Dimmer may feel warm to the touch during normal operation.
8. Clean dimmers with a soft damp cloth only. Do not use any
chemical cleaners.
SUNNATA
FCC Supplier Declaration of Conformity / IC:
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause interference, and
(2) this device must accept any interference, including
interference that may cause undesired operation.
CAN ICES-5 (B)/NMB-5(B)
Advanced Programming Options
These advanced programming options can be changed for your dimmer:
1. Adjust the high-end light output
2. Turn the light bar Off during Idle and Nightlight states
3. Adjust the light bar brightness higher or lower
4. Change the Preset Light Level or Unlock the Preset to recall previous level
See the Sunnata Advanced Programming Mode Application Note #734
(P/N 048734) at www.lutron.com/SunnataSupport for details on how to
change these settings.
For Troubleshooting see reverse side
STCL-153P
120 V~ 60 Hz
Use our mobile friendly self-paced
installation tool:
www.lutron.com/wiringwizard
Find more product information:
www.lutron.com/support
- Videos
- Frequently Asked Questions
Call us:
U.S.A. | Canada | Caribbean
1.844.LUTRON1 (588.7661) (24/7)
Mexico
+1.888.235.2910
Others
+1.610.282.3800
F
A
S
S
F
A
S
S
F
A
S
S
F
A
S
S
F
A
S
S
F
A
S
S
OFF
ON
WARNING: ELECTRIC SHOCK HAZARD.
May Result in Serious Injury or Death.
Disconnect power before servicing or installing.
1
Determine wiring type
2
Turn power OFF at circuit breaker
5
Connect the new dimmer
6
Mount dimmer using the provided screws
7
Turn power ON at circuit breaker
8
Operation
9
Set low-end trim
3
Remove existing device
Disconnect wires.
4
Check ratings
a. For lights controlled from one location (single-pole):
Proceed to step 2 below.
On
On
Off
Off
MAXIMUM RATINGS FOR MIXED LOAD TYPES
0 W + 600 W 500 W 400 W
1 W – 25 W + 500 W 400 W 300 W
26 W 50 W + 400 W 300 W 200 W
51 W 75 W + 300 W 200 W 100 W
76 W 100 W + 200 W 100 W 50 W
101 W 125 W + 100 W 50 W 0 W
126 W 150 W + 0 W 0 W 0 W
(Front Accesible Service Switch)
Pull tab out for bulb replacement.
LFCA
CFL
AFC
CFL
+
Low-End Trim:
1. Touch the middle of light bar
continually for about
6 seconds. (Do not depress
the OFF button).
2. Slide finger on light bar to
adjust to desired brightness.
3. To exit, press the OFF
button.
Black
Blue
Black
Green
(ground)
b. For lights controlled from two locations (3-way), see reverse side:
Rewiring in both locations is required.
c. 3 or more locations:
Product is not compatible.
See www.lutron.com/dimmers for options.
For videos and step by step instructions, please see
www.lutron.com/wiringwizard
FASS Switch
W1
W1
W2
W2
Adjust:
(Light Bar)
Touch the light bar to set
the lamps to desired level.
Slide to adjust the
light level.
NOTE: For advanced programming options see the Sunnata
Advanced Programming Mode Application Note #734 (P/N 048734)
at www.lutron.com/SunnataSupport
Single gang End of gang Middle of gang
OPTIONAL FOR INCANDESCENT / HALOGEN
Incadescent / Halogen
LED I/H
LED I/H
LED I/H
LED I/H
LED
For lights controlled from one location
(For lights controlled from two locations, see instructions on reverse)
Ground wire
(green or bare copper)

Summary of content (4 pages)