Drawing
2
|
Lutron® 24/7 Technical Support—800.523.9466
product specifications
08.30.11
369-303b
HomeWorks® QS RF Hybrid seeTouch® Keypads
Specifications
Model Numbers Keypads: HQRD-H1RLD-XX, HQRD-H2RLD-XX, HQRD-H3BSRL-XX,
HQRD-H4S-XX, HQRD-H5BRL-XX, HQRD-H6BRL-XX,
Engraved Replacement Kit: RKD-
H1RLD
-XX-E, RKD-
H2RLD
-XX-E,
RKD-
H3BSRL
-XX-E, RKD-
H4S
-XX-E, RKD-H5BRL-XX-E, RKD-H6BRL-XX-E
Remote Dimmer: HQD-RD-XX
Power 120 V ~ 50 / 60 Hz
Typical Power
Consumption
0.75 W
Test conditions: load is off, all backlights on medium intensity, two status
LEDs on (two presets active), keypad powered at 120 V~.
Regulatory Approvals UL, CSA, NOM, FCC, IC, COFETEL
Environment Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C),
0% to 90% humidity, non-condensing. Indoor use only.
Communications Hybrid Keypads communicate with the HomeWorks
® QS system through
Radio Frequency (RF) and must be located within 30 ft (9 m) of a
repeater. Remote dimmers are not required to be within a specific range
of a repeater.
ESD Protection Tested to withstand electrostatic discharge without damage or memory
loss, in accordance with IEC 61000-4-2.
Surge Protection Tested to withstand surge voltages without damage or loss of operation,
in accordance with IEEE C62.41-1991 Recommended Practice on Surge
Voltages in Low-Voltage AC Power Circuits.
Power Failure Power failure memory: should power be interrupted, the control will
return to its previous state when power is restored.
Mounting Requires a U.S. wallbox. 3 ½ in (89 mm) deep recommended, 2 ¼ in
(57 mm) deep minimum. If mounting one control above another, leave at
least 4 ½ in (114 mm) vertical space between them.
Wiring Uses conventional 3-way and 4-way wiring.
Warranty 8 Year Limited Warranty. http://www.lutron.com/resiinfo
• Keypadbuttonsareprogrammabletoselect
scene or room preset levels or positions.
• Atthepressofakeypadbutton,lightsfadeON
or OFF to desired levels and shades/draperies
open or close to desired positions.
• Adjustablebacklightintensity.
• Prepaidengravingincluded.Redeemablefor
one engraved Replacement Kit.
Design Features
• Internal dimmer is assigned to top button by
default, but can be reassigned to any button on
the Hybrid Keypad. Tap top button to toggle load
ON / OFF.
• Internal dimmer can be assigned to any
programmable input.
• Can be installed in two-wire or neutral wire
applications.
• Can be installed in either single location or
multi-location (with Remote Dimmer) installations.