Thermostat Value Series RS4000, RS5000 and RS600 UNI-LINE® PRODUCT KNOWLEDGE © 2009 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys are proprietary marks of Invensys or its subsidiaries. All third party trademarks and service marks are the proprietary marks of their respective owners.
Subjects We Will Cover In This Session • Thermostat Products and Features • Robertshaw® Value RS456 Series • Manufacturer Comparison • Installation and Set-Up • Powering Thermostat • Pop-Up Wizard • Password Protection • System Test Mode • Where to Find Information • Q&A
Thermostat Series – Product Overview • Robertshaw® i2 Deluxe Series – Setup Wizard – Time of day zoning – Independent remote and outdoor sensor terminals • RS4000, RS5000, and RS6000 Value Series – Pop-up Configuration Wizard – Auto Changeover – Circulating Fan • RS2000 and RS3000 Economy Series – Adjustable Temperature Differential – Worry-Free Memory Retention – Low Temperature Freeze Protection – Filter Indicator
Nomenclature for RS Series Application 2 = Non-Programmable, Economy Series 0 = Standard Thermostat 3 = 5-2 Day Programmable, Economy Series 4 = Non-Programmable, Value Series 5 = 5-2 Day Programmable, Value Series 6 = 7-Day Programmable, Value Series Number of Cooling Stages Number of Heating Stages
Robertshaw® Value Series Thermostats • RS4000 Series; Non-programmable – RS4110 1 Heat / 1 Cool; Universal Application* – RS4220 2 Heat / 2 Cool; Universal Application* – RS4320 3 Heat / 2 Cool; Universal Application* • RS5000 Series; Programmable; (5-2 Day Schedule) – RS5110 1 Heat / 1 Cool; Universal Application* – RS5220 2 Heat / 2 Cool; Universal Application* • RS6000 Series; Programmable (7 Day Schedule) – RS6110 1 Heat / 1 Cool; Universal Application* – RS6220 2 Heat / 2 Cool; Universal A
Features: RS4000, RS5000 & RS6000 Series • Pop-up Wizard • Engineered True Blue backlight display • Largest Temperature Display Character Size • Soft Touch Keys • Set-up Test Mode • Auto Changeover • Circulating Fan • Low Temperature Freeze Protection • High Temperature Protection • High / Low Temperature Limits • Easy Change Battery Access • California Title 24 Compliant • 5 Year Limited Warranty
RS4000, RS5000 And RS6000 Series Installation And Set-Up
Installation - Mounting
Wiring Diagram Including Heat Pump Switch
Poll Question #1 G terminal (Green) connects to: a) Fan relay b) Condenser c) Humidifier solenoid W terminal (White) connects to: a) Emergency heat G W b) First stage heating relay c) Fan relay Y terminal (Yellow) connects to: a) Heat contact b) Reversing Valve c) Cooling contact Y
Installation – Initial Set-up
Installation – Powering Thermostat • Robertshaw® Value Series Thermostats may be powered by either – 24V AC or 2 (AA) Batteries • Thermostats with batteries will continue to function if 24V AC fails • Installing Batteries – Battery tray is a drawer in the thermostat body – Pinch both sides and pull tray out from bottom – Install two AA batteries – Follow polarity as shown on inside tray – Slide tray back into the body • Battery Charge mode has two levels : – Level 1: Low battery icon. Change batteries soon.
Poll Question #2 Robertshaw® Value Series Thermostats are powered by: A. 24 Volts AC or AA Batteries B. Line Voltage or AAA Batteries C. Line Voltage only D.
Access to Pop-Up Wizard After Start up • Press the UP and DOWN buttons simultaneously for 3 seconds • Pop-Up Wizard will initiate
Pop-Up Wizard Configuration Chart Displayed Choice Default SCAL F° or C° F° CLOC 12 or 24 hour 12 LITE 1=always on, 0=off 0 DIFF Set Differential, 0.5-3 F° or 0.5-1.5 C° 1 F° DIF2* Set 2nd Stage Differential, 1-6 F° or 0.
Password Protection • Press UP and HEAT/COOL buttons simultaneously • Hold for 10 seconds • Use the UP and DOWN to enter the desired digit • Use the HEAT/COOL button to move to the next digit • The password will be saved after 10 seconds • A lock will appear in the: – Upper left hand corner for RS4000 series – Lower right hand corner for RS5000 and RS6000 series • Default passwords are the following: – RS4000 is 81 – RS5000 and RS6000 is 8115
System Test Mode • Press FAN and HEAT/COOL buttons simultaneously • Hold for 10 seconds • Press the HEAT/COOL button to turn on heat • Only FAN, HEAT/COOL and Start/Stop buttons are active • A second press will turn on 2nd stage of heat (on multistage models) • Continuous pressing of HEAT/COOL button will turn on cooling • Short Cycle protection is not enabled.
Staging Parameters Single Stage Models Demand Conventional (Non – HP) Heat Pump (HP) First Stage Cool Y1 & G Y1 & G & O First Stage Heat W1 & G (note, G is Off for Gas, On for Electric) Y1 & G & B Multi Stage Models Demand Conventional (Non – HP) Heat Pump (HP) First Stage Cool Y1 & G Y1 & G & O Second Stage Cool Y1& Y2 & G Y1 & Y2 & G & O First Stage Heat W1 & G Y1 & G & B Second Stage Heat (2H/2C) W1 & W2 & G Y1 & W2 & G & B Second Stage Heat (3H/2C) W1 & W2 & G Y1 & W2 & G & B
Poll Question #3 What is activated when UP and DOWN buttons are pushed simultaneously for 10 seconds? A. Password Setup B. System Test Mode C. Pop-Up Wizard D.
RS456 Value Series – Manufacturer Comparison WhiteRodgers Features Robertshaw® Family Model or SKU RS4000 / RS5000 RS6000 TH5000 TH6000 1F80 series 3000 5000 DMH110 / DHP2120 TX500E / HP2110 Auto Changeover 9 9 8 8 8 Pop-Up Wizard 9 8 8 8 8 Test Option 9 8 8 8 8 High & Low Temp Limits 9 8 8 8 8 Freeze & Heat Protection 9 8 8 8 8 Universal Equipment 9 8 9 8 8 Adjustable Compressor Short Cycle 9 8 9 8 8 Circulating Fan 9 8 8 9 8 Adjustable 2nd Stage Del
RS456 Value Series – Pros and Cons Features Auto Changeover Pop-Up Programming Wizard Pros for Robertshaw® Better Comfort in Spring & Fall Installation Codes Limits Adjustments Circulating Fan Effective Use of IAQ Equipment Power Thermostat Requires Complicated Minimizes Temperature Equipment & More Trips to Simplifies Start-up & High & Low Temp Universal Competition Higher Energy Use Less Use of IAQ Equipment Gas, Electric, Oil, Heat Pump Requires Separate Battery or 24V SKU’s
RS456 Value Series – Value Proposition Wholesaler / Distributor Contractor End-User Less SKU’s on Shelf Less Programming Greater Comfort Easier to Sell Faster Programming And Start-up Setup Right the First Time High & Low Temperature Limits More Features Offers Greater Control Minimizes Temperature Swings Circulating Fan Upsell Other Products Better Use of IAQ Equipment Comfort & Energy Savings Universal Equipment & Power Less Inventory to Carry Right Product for Right Job Flexibility on
More Features + Less Money = Value Series RS456 Series
Sales Tools for the Value Series • Sell Sheet Part Numbers: 150-2089, 150-2090, & 150-2091
Choosing the Right Thermostat • Trusted Brand – Dependable and reliable with a history of innovative products. • Universal Products – The right product for the job. Simplifies inventory. Assured compatibility. • Availability – Where you need it, when you need it. • Quality – Works right the first time. • Contractor Friendly – Simple set-up and programming menus. Saves time & money. Eliminates second guessing. • Support – Sales and technical support for all your needs.
Troubleshooting Furnaces There is NO HEAT! Switch on side of furnace 9Most furnaces will have an ON/OFF wall switch next to them Fuses and/or circuit breaker 9Make sure fuses and/or circuit breaker have been checked Front furnace cover 9Many furnaces will not operate with cover off Furnace filter 9Make sure furnace filter is clean and clear
Troubleshooting Thermostats There is NO HEAT! Thermostat settings 9Is thermostat in HEAT mode and calling for heat? Wiring 9Is thermostat wired properly and is jumper there? Relays (if applicable) 9Are relays clicking on a call for heat? Jumping terminals 9Does furnace cycle if the Ground and W terminals are jumped? NOTE: Remember most all gas furnaces will run the inducer fan for a couple of minutes before the actual blower turns on. This inducer fan may not be heard if the furnace is in a remote location.
Website Tools: www.Uni-Line.
When You Have Uni-Line® Questions Telephone: Technical Service 1-800-445-8299 Technical Service Fax 1-630-260-7294 Customer Service 1-800-304-6563 Customer Service Fax 1-800-426-0804 Website: Uni-Line® Catalog Website: www.Uni-Line.com Cross Reference Website: www.uni-line.com/templates/xrefsearch.aspx General Information Websites for: Robertshaw®, Paragon®, Eliwell™, Ranco®, and Publication Zone® www.InvensysControls.com www.RobertshawTstats.com www.ToolBox.InvensysControls.