User Guide

Troubleshooting Poor Temperature Regulation
• This page lists problems that may affect the temperature performance of your LUX
thermostat with suggested resolutions.
• For more detailed information please refer to the instructions that came with your
thermostat.
Model
LV2 / LV21
Problem
Resolution
Heats more than 5 degrees past
its displayed set temperature
Verify that your thermostat's electrical connections
are clean and tight.
Verify that your units placement and mounting are
optimum per the installation section of its manual.
Slowly rotate the dial from full left to full right.
Listen carefully for a small click in both directions.
These two clicks should be near the approximate
room temperature location on the knob. NOTE:
there will be an additional click heard right near the
OFF position on the dial, and the above clicks that
are mentioned should be in addition to the click
near the OFF position.
Replace unit. There are no user serviceable parts.
No heat when expected
Refer to wiring troubleshooting to verify that it is
wired according to the units proper wiring diagram.
Verify that all connections to your thermostat are
clean and tight.
If room temperature is greater than 90F the unit will
not close its switch and call for heat.
Rotate the dial to its highest setting. Heat should
operate immediately if the approximate room
temperature is less than around 90F degrees.
Heat Test
Slowly rotate the dial toward its lowest setting.
Listen carefully for a small click near room
temperature. When it is heard, the unit should
switch off heat immediately. Slowly rotate the dial
toward its higest setting. Listen carefully for a small
click near room temperature. When it is heard, the
unit should switch on heat immediately.
Advanced Troubleshooting
This thermostat is designed to switch hazardous
voltage. Qualified service personnel may use the
following information to troubleshoot the system.
NOTE: Only the L1-IN/OUT pole is broken during
normal temperature control. The L2-IN/OUT pole
is a pass-through and is always live unless the

Summary of content (3 pages)