Installation & Assembly

www.allstarlighting.com
INSTALLATION GUIDE
33 Randolph Ave. • Avenel NJ 07001 | 732-882-1500
1
IMPORTANT SAFETY INSTRUCTIONS
For direct replacements for specific fluorescent lamps (32W/48T8,
30W/48T8, 28W/48T8, 25W/48T8), please follow steps below:
RETROFIT FLUORESCENT LUMINAIRE WITH ELECTRONIC
BALLAST
LR34195, LR34196, LR34197, LR34198, LR34199T8 4’
STEP 1: Shut off power before work
STEP 2: Remove existing fluorescent tube(s), diffuser (if applicable) and
open the ballast cover.
STEP 3: Disconnect luminaire supply wirings L and N to branch circuit as
shown in FIG. 1
STEP 4: Original circuit as shown in Fig. 2. Cut lampholder leads “1,2,3,4, L,
N”, then check whether the lampholder is shunted. Cut as far away from the
lampholders to allow for longer lengths of wire at both lampholders. Note:
Ballast must be retained in place.
Luminaire
Branch Circuit
Lampholder
L N
TO USE AS LED LUMINAIRE CONVERSION RETROFIT KIT
DANGER - RISK OF SHOCK - DISCONNECT POWER BEFORE
INSTALLATION.
THE RETROFIT KIT INCLUDES INSTALLATION INSTRUCTIONS, LED LAMP,
LUMINAIRE MARKING LABELS.
THE T8 LED TUBES ARE INTENDED TO RETROFIT LISTED SURFACE
MOUNTED, TYPE NON-IC OR TYPE IC RECESSED MOUNTED FLUORES-
CENT LUMINAIRES WITH OR WITHOUT DIFFUSER FOR A MAXIMUM OF
FOUR LAMPS WITH A MINIMUM DISTANCE OF 11 CM BETWEEN LAMPS; PR
RETROFIT SURFACE MOUNTED LISTED FLUORESCENT LUMINAIRES
WITHOUR DIFFUSER FOR A MAXIMUM OF SIX LAMPS WITH A MINIMUM
DISTANCE OF 5.5 CM BETWEEN LAMPS.
THE PRODUCTS ARE INTENDED TO BE USED IN DRY AND DAMP LOCA-
TIONS ONLY.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE
APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE
CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
WARNING - RISK OF FIRE OR ELECTRIC SHOCK: The electrical rating of
these products is 120-277V, the installer must determine whether they have
120-277V at the luminaire before installation.
WARNING - RISK OF FIRE OR ELECTRIC SHOCK: LED Retrofit Kit installa-
1. Switch-off power to the luminaire.
2. Remove diffuser (if provided)
3. Remove the existing fluorescent lamps from the luminaire.
4. Install the LED T8 replacement lamp
5. Replace diffuser (if removed in Step 2)
6. Switch-on power to the luminaire.
1
OFF
2
Fluorescent Lamp
3
Fluorescent Lamp
4
LED T8
5
LED T8
6
ON
tion requires knowledge of luminaire electrical systems. If not qualified, do not
attempt installation. Contact a qualified electrician.
WARNING - RISK OF FIRE OR ELECTRIC SHOCK: Install this kit only in the
luminaires that have the construction features and dimensions shown in the
photographs and/or drawings and where the input rating of the retrofit kit does
not exceed the input rating of the luminaire.
WARNING - To prevent wiring damage or abrasion, do not expose wiring to
edges of sheet metal or other sharp objects.
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF
WIRING OR ELECTRICAL COMPONENTS DURING KIT INSTALLATION.
Installers should not disconnet existing wires from lamp holder terminals to
make new connections at lamp holder terminals. Instead installers should cut
existing lamp holder leads away from the lamp holder and make new electrical
connections to lamp holder lead wires by employing applicable connectors.
THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE
WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED
BY AUTHORITIES HAVING JURISDICTION.
DO NOT USE WITH DIMMERS
RISK OF ELECTRIC SHOCK - USE IN DRY AND DAMP LOCATIONS ONLY
THIS DEVICE IS NOT INTENDED TO BE USED WITH EMERGENCY EXITS
FIG. 1
FIG. 2
Lampholder
N L
Lampholder
1 2 43
BALLAST

Summary of content (2 pages)