Installation Guide
www.allstarlighting.com
PACKAGE CONTENTS
INSTALLATION GUIDE
LR23790, LR23791
33 Randolph Ave. • Avenel NJ 07001 | 732-882-1500
1
4” DOWNLIGHT ROUND TRIM CCT CHANGE
4” DOWNLIGHT
4”
E26 BASE
ADAPTER
FIGURE 2
FIGURE 3
FIGURE 1
RECESSED HOUSING
CEILING
OPEN SOCKET
CCT SELECT
Ø5.09”
3.11”
RECESSED HOUSING
1. Turn off the main power prior to installation
2. Remove the existing trim and bulb to gain access to the socket.
3. Screw in the E26 socket adapter into the open socket. (FIGURE 1)
4. Plug in the quick connector and select CCT. (FIGURE 2)
5. Once connector is attached, squeeze spring clips and gently push trim into fixture
opening until flush with ceiling. (FIGURE 3)
USE ONLY FIXED LUMINAIRE WITH MIN. LAMP COMPARTMENT DIMENSIONS 102mm (D) x 140mm (H)
UTILISER UNIQUEMENT LUMINAIRE FIXE AVEC MIN. LAMPE DIMENSIONS DU COMPARTIMENT
102mm (D) x 140mm (H)
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALLATION OF THIS RETROFIT KIT
REQUIRES A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE
LUMINAIRE’S ELECTRICAL SYSTEM AND THE HAZARD INVOLVED. IF NOT QUALIFIED, DO NOT
ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.
AVERTISSEMENT – RISQUE D`INCENDIE OU DE CHOC ÉLECTRIQUE. L`INSTALLATION DE CE
NÉCESSAIRE DE MODERNISATION EXIGE UNE PERSONNE FAMILIÈRE AVEC LA CONSTRUCTION
ET LE FONCTIONNNEMENT DU SYSTÈME ÉLECTRIQUE DU LUMINAIRE ET DES RISQUES
ASSOCIÉS. TOUTE PERSONNE QUI N`EST PAS QUALIFIÉE NE DOIT FAIRE AUCUNE TENTATIVE
D`INSTALLATION ET DOIT CONTACTER UN ÉLECTRICIEN QUALIFIÉ.
WARNING – RISK OF FIRE OR ELECTRIC SHOCK. INSTALL THIS KIT ONLY IN THE LUMINAIRE
THAT HAS THE CONSTRUCTION FEATURES AND DIMENSIONS SHOWN IN THE PHOTOGRAPHS
AND/OR DRAWINGS AND WHERE THE INPUT RATING OF THE RETROFIT KIT DOES NOT
EXCEED THE INPUT RATING OF THE LUMINAIRE.
AVERTISSEMENT – RISQUE D`INCENDIE OU DE CHOC ÉLECTRIQUE. N`INSTALLER CE
NÉCESSAIRE QUE DANS LE LUMINAIRE DONT LES CARACTÉRISTIQUES DE CONSTRUCTION ET
LES DIMENSIONS SONT CONFORME À CELLES ILLUSTRÉES DANS LES PHOTOS ETÉOU LES
DESSINS ET DONT LA PUISSANCE D`ENTRÉE NOMINALE DU NÉCESSAIRE DE MODERNISATION
NE DÉPASSE PAS CELLE DU LUMINAIRE.
DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLOSURE OF WIRING OR ELECTRICAL
COMPONENTS DURING KIT INSTALLATION.
IL EST INTERDIT DE FAIRE OU DE MODIFIER UNE OVERTURE DANS UN BOÎTIER DE CÂBLAGE OU DE
COMPOSANTS ÉLECTRIQUES AU COURS DE L`INSTALLATION DU NÉCESSAIRE.
WARNING – TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF
SHEET METAL OR OTHER SHARP OBJECTS.
AVERTISSEMENT – AFIN DE PRÉVENIR L`ENDOMMAGEMENT OU L`ABRASION DES CÂBLES,
ÉVITER TOUT CONTACT ENTRE CES DERNIERS ET LE BORD D`UN OBJET TRANCHANT TEL
QU`UNE TÔLE.
THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF
THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT
MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND
APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR
NATIONAL REGULATION FOR ELECTRICAL INSTALLATIONS.
LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D`UN
LUMINAIRE LORSQUE LA PERTINENCE DE LA COMBINAISON DOIT ÊTRE DÉTERMINÉE PAR
LES AUTORITÉS COMPÉTENTES. CE PRODUIT DOIT ÊTRE MIS EN PLACE PAR UN ÉLECTRICIEN
QUALIFIÉ CONFORMÉMENT AUX CODES ÉLECTRIQUES APPROPRIÉS APPLICABLES. LE GUIDE
D`INSTALLATION NE SUPPLANTE PAS LES RÈGLEMENTS LOCAUX OU NATIONAUX EN
MATIÈRE D`INSTALLATIONS ÉLECTRIQUES.
THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS
NE CONVIENT PAS AUS SORTIES DE SECOURS
THIS LUMINAIRE HAS BEEN MODIFIED AND CAN NO LONGER OPERATE THE ORIGINALLY
INTENDED LAMP.