INSTALLATION GUIDE
LR23952, LR23954
33 Randolph Ave. • Avenel NJ 07001 | 732-882-1500
1
6” & 8” 4 CCT & WATTAGE SELECTABLE COMMERCIAL DOWNLIGHT
1. SELECT DESIRED LUMEN OUTPUT AND CCT. FIGURE 1
2. SHUT POWER OFF TO THE FIXTURE. INSERT LAMP CONDUIT INTO THE J-BOX AND
CONNECTING THE WIRES. WIRE NUT THE GROUND (GREEN) WIRE IN THE JUNCTION BOX.
WIRE NUT THE BLACK INPUT WIRE WITH THE BLACK WIRE FROM THE J-BOX AND WIRE NUT
THE WHITE INPUT WIRE WITH THE WHITE WIRE FROM THE J-BOX. WIRE NUT THE PURPLE
INPUT WIRE WITH THE PURPLE WIRE FROM THE J-BOX AND WIRE NUT THE GREY INPUT
WIRE WITH THE GREY WIRE FROM THE J-BOX. IF THE PURPLE AND GREY WIRES ARE NOT IN
USE, CAP THEM WITH A WIRE NUT. FIGURE 2
FIGURE 1
FIGURE 2
INSTALLATION WITHOUT EXISTING FRAME
FIGURE 3
3. INSTALL JUNCTION BOX COVER PLATE. FIGURE 3
FIGURE 4
4. INSTALL LED KIT BY FITTING BOTH RETENTION TABS UPWARD. FIGURE 4
FIGURE 5
4. PUSH THE KIT UNTIL IT SITS FLUSH AGAINST THE CEILING. FIGURE 5
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE. LUXRITE FIXTURES MUST BE WIRED IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
PROPER GROUNDING IS REQUIRED FOR SAFETY. THIS PRODUCT MUST BE
INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT
AND THE HAZARDS INVOLVED. THIS INSTALLATION GUIDE DOES NOT SUPERSEDE
LOCAL, NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.
WARNINGS
RISK OF ELECTRIC SHOCK - DISCONNECT POWER AT FUSE OR CIRCUIT BREAKER
BEFORE INSTALLING OR SERVICING.
• TO PREVENT EARLY LAMP FAILURE, LAMP SHOULD ONLY BE INSTALLED IN
OPERATING ENVIRONMENTS RANGING BETWEEN –30° C AND + 40° C (–22°F AND
104°F)
• NO USER SERVICEABLE PARTS INSIDE, TO AVOID ELECTRICAL SHOCK DO NOT DISASSEM-
BLE PRODUCT.
• RISK OF FIRE OR ELECTRIC SHOCK - LED RETROFIT KIT INSTALLATION REQUIRES
KNOWLEDGE OF LUMINAIRES ELECTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT
ATTEMPT INSTALLATION. CONTACT A QUALIFIFED ELECTRICIAN.
• RISK OF FIRE OR ELECTRIC SHOCK - INSTALL THIS KIT ONLY IN LUMINAIRES THAT
HAVE THE CONSTRUCTION FEATURES, MIN DIMENSIONS, AND WHERE THE INPUT
RATING OT THE RETROFIT KIT DOES NOT EXCEED THE INPUT RATING OF THE
LUMINAIRE.
• DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN ENCLUSIRE OF WIRING OR
ELECTRICAL COMPONENTS DURING KIT INSTALLATION.
• TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF
SHEET METAL OR OTHER SHARP OBJECTS.
• INSTALLERS SHOULD NOT DISCONNECT EXISTING WIRES FROM LAMPHOLDER
TERMINALS TO MAKE NEW CONNECTIONS AT LAMPHOLDER TERMINALS, INSTEAD,
INSTALLERS SHOULD CUT EXISTING LAMPHOLDER LEADS AWAY FROM THE
LAMPHOLDER AND MAKE NEW ELECTRICAL CONNECTIONS TO LAMPHOLDER LEAD
WIRES BY EMPLOYING APPLICABLE CONNECTORS.
• THIS RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE
SUSTABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES
HAVING JURISDICTION.
• THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS.
• CAUTION - RISK OF FIRE - CONSULT A QUALIFIED ELECTRICIAN TO ENSURE
CORRECT BRANCH CIRCUIT CONDUCTOR. MIN. 90º SUPPLY CODUCTORS.