LLDP Confi g
SNMP
Notifi cation
Interval:
Specify the interval of Trap Messages to be sent from the local Device to
Network Management system. The default value is 5.
Fast Start Count:.
When the Port’s LLDP state changes from Disable (Rx_Only) to Enable
(Tx&Rx or Tx Only), the fast start mechanism will be Enabled. This shortens
the transmit interval to one second, and several LLDPDUs will be sent out
(the number of LLDPDUs equals this parameter). The default value is 3.
CAUTION: LLDP Confi g settings will be restored to defaults if the Switch
is restarted and you have not selected Save Confi g from the
main menu and saved your running confi guration to non-
volatile memory.
14.1.2 Port Confi g
On this page you can confi gure the Port(s) LLDP parameters.
Choose the menu LLDP>>LLDP Confi g>>LLDP Port Confi g to load the following page:
Figure 14-2 LLDP Port Confi g