Professional Weighing Equipment Intelligent Weighing Machine MCT PLUS SERIES WITH CHECK-WEIGHING FUNCTION Operating Manual
Declaration of Conformity Declaration of conformity for apparatus with CE mark We hereby declare that the product to which this declaration refers conforms to the following standards. Electronic scale: MCT Plus Mid Counting Scales Mark applied Imperial version Metric version MCT PLUS 3 MCT PLUS 7 MCT PLUS 16 MCT PLUS 33 MCT PLUS 66 MCT PLUS 1500 MCT PLUS 3000 MCT PLUS 7500 MCT PLUS 15000 MCT PLUS 30000 EU Directive Standards 2004/108/EC EN 61326-1: 2006 Date: 14. 11.
Customer Service USA LW Measurements LLC, 3510 Industrial Drive, Unit H Santa Rosa, CA 95403 USA Tel: (707) 542-2185 FAX: (707) 542-3285 EUROPE LW Measurements Europe Ltd Chalkwell Park House 700 London Road Westcliff-on-Sea Essex SS0 9HQ United Kingdom Tel: 01702-476700 Fax: 01702-477380 ASIA LW Measurements PTY Ltd Block 1004, Toa Payoh North #03-16 Singapore 318995 Tel: (65) 6458 3438 HP: (65) 8119 3401 http://www.lwmeasurements.
Introduction What you should know about these Operating Instructions: Tree® Professional Weighing Equipment products are simple to operate. Nevertheless, you should read through these operating instructions in their entirety, so that you can make optimum use of the full potential and the diverse possibilities of the weighing machine in your daily work.
Contents Section 1 Heading Safety 1.1 Representation and symbols 1.2 Safety recommendations 2 Your weighing machine 2.1 Construction and functions 2.1.1 Construction of the weighing machine 2.1.2 Functions of the weighing machine 2.2 Application, conformity 2.2.1 Correct use of the weighing machine 2.2.2 Conformity 2.3 Data and parameters 2.3.1 Technical data 3 Getting started with your weighing machine 3.1 Unpacking the equipment 3.2 Scope of delivery 3.3 Assembling your weighing machine 3.
5.2 Sample setting 5.2.1 Number setting (for counting any unknown weight) 5.2.2 Unit weight setting (when unit weight is known) 5.3 Alarm function 5.4 Unit weight enhancement 5.5 Lack of piece weight 5.6 Hi/Lo check-weighing with counting 6 Calibration 7 Maintenance and service 8 Transport and storage 8.1 Transportation and shipping 8.
1 Safety 1.1 Representations and symbols Important instructions, which involve safety, are highlighted with the appropriate mark: 1.2 Safety recommendations When using the weighing equipment in surroundings with increased safety requirements, the corresponding regulations must be observed. The weighing machine may only be used with the power adapter supplied exclusively for use with the weighing machine.
The weighing machine must not be operated in an area subject to explosion risks. Keep this weighing machine away from water – this machine is NOT water resistant. Shock, injury and electrical damage can occur if used in a wet location. Care must be taken when weighing liquids to ensure that no liquid is spilled into the inside of the weighing machine or into connections on the rear of the equipment or the power adapter.
2 Your weighing machine 2.1 Construction and functions 2.1.1 Construction of the weighing machine The weighing machine consists of the weighing machine body (1), the platter (2), the weighing machine (3) the adapter, (4) this operating manual. Figure 2.
2.1.2 Functions of the weighing machine The MCT Plus Series are high-quality electronic precision weighing machines designed to function as counting scales and check-weighers with the following specifications: 1. Imperial weight unit version Model number Capacity Division Weighing pan Size MCT PLUS 3 3 lb 0.0001 lb 7.6 x 10 in MCT PLUS 7 7 lb 0.0002 lb 7.6 x 10 in MCT PLUS 16 16 lb 0.0005 lb 7.6 x 10 in MCT PLUS 33 33 lb 0.001 lb 7.6 x 10 in MCT PLUS 66 66 lb 0.002 lb 7.
2. Metric weight unit version Model number MCT PLUS 1500 MCT PLUS 3000 MCT PLUS 7500 MCT PLUS 15000 MCT PLUS 30000 Package (Standard carton) Capacity Division Weighing pan Size 1500 g 0.05 g 193 X 254mm 3000 g 0.1 g 193 X 254mm 7500 g 0.2 g 193 X 254mm 15 kg 0.0005 kg 193 X 254mm 30 kg 0.001 kg 193 X 254mm 3 35 X 31 X 16.5(cm ) Package (Master carton) 4 Units in one box: 64.
The built-in versatile weighing programs allow you to use the MCT PLUS Series weighing machines not only for accurate weighing but also for components counting.
Figure 2.2 Details of your weighing machine Fig 2.2.1 Display Fig 2.2.2 Numeric Keypad Leveling bubble Fig 2.2.
Fig 2.2.4 Underside of unit Battery compartment (Rechargeable battery included) On/Off switch Battery compartment cover 2.2 Application, conformity 2.2.1 Correct use of the weighing machine The weighing machine may only be used for the weighing of solid-materials and liquids filled into secure containers. The maximum allowable load of the weighing machine must never be exceeded; otherwise the weighing machine may be damaged.
The power adapter produced for the operation of the weighing machine and intended exclusively for this application complies with the appropriate electrical protection class. 2.3 Data and parameters 2.3.
Check the weighing machine immediately after unpacking for externally visible damage. If you should find transport damage, please inform your service representative immediately. If the unit is not to be used immediately after purchase but rather at a later time, it should be stored in a dry place where fluctuations in temperature are as minimal as possible. (See Chapter 7 Transport, storage).
vibration and not in direct sunlight. The surface should not be magnetic and should be located away from doors, windows, heaters, air conditioners and fans. To summarize: Put the weighing machine on a solid, firm and preferably vibrationproof, horizontal base Make sure that the weighing machine cannot be shaken or knocked over Protect from direct solar radiation Avoid drafts and excessive temperature fluctuations 3.
measurements, the machine must again be carefully leveled after each relocation. Fig. 1 Correct leveling with the aid of the bubble level and adjusting feet. 3.7 Calibration of the weighing machine Since the Earth’s gravity is not the same everywhere, each weighing machine must be adjusted to compensate for the gravity differences at each location in accordance with the underlying physical weighing principles.
4 Working with the application menu using the Numeric Key-Pad 4.1 Display messages and key functions 4.1.1 Display messages 1. The STABLE icon indicates when the readings are stable. 2. The ZERO icon indicates when the weights are tared to zero. 3. The LO-BAT icon indicates when the battery is running out of power. 4. The PCS icon indicates when the pieces counting function is applied. 4.1.2 Display & Key Functions 1.
3. TOTAL DISPLAY is the accumulated total pieces on the scale. 4. The ZERO INDICATOR turns on when the weighing machine is in Zero position. 5. The TARE INDICATOR turns on when this function is used. 6. LOW SAMPLE WEIGHT turns on when the sample number is not large enough for accurate counting. 7. LOW UNIT VALUE turns on when sample unit weight is not heavy enough for accurate counting. 8. NUMERIC (0-9) KEYS are used for setting numeric data for sample number, sample weight or to limit the HI / LO settings.
18. Press the TOTAL key to switch between normal counting and recalling memory data. 4.1.3 Function setting - Turn off the weighing machine using the hard switch located on the bottom of the weighing machine. - Press and hold UNIT WEIGHT key and then turn on the weighing machine. The display will show “------“ and then “b = XX” (beeper), on the first line, A-XX (auto off) on the second line and “L = XX (backlight) on the third line. - Press the QTY/SET key to toggle between activating the beeper on or off.
5 Operation 5.1 Tare 5.1.1 Clearing the tare weight - Place the empty container on the platter. Press the TARE key. The display will show 0.00000. - When the container is removed from the platter, the WEIGHT display will show a minus (-) weight value which is the weight of the container. 5.1.2 Clearing the previous tare weight - Remove weight from the platter and then press the TARE key. The Tare indicator will turn off and the WEIGHT display will return to Zero. 5.2 Sample setting 5.2.
Press the CE key again to cancel the previous unit weight and sample setting. 5.3 Alarm function - To avoid counting errors, this scale has a useful alarm function to inform the operator of a counting error in the event of low sample size or low sample weight. - The Low Sample Weight cursor on the display will turn on if the total weight of the sample is below the limit value. The scale will start counting but the error may be high. - Press the CE key.
- Press the QTY/SET key to enter the quantity alarm menu. - Press the ZERO key to turn on the check weighing. Display will show CH=ON. Press the ZERO key again and the display will show CH-OFF which means the quantity alarm function has been turned off. - To set the lower and upper count limit, press the TARE key to select the hi/lo limits. For example, “L = 990,” press 990 on the numeric keypad, then TARE to switch over to: H = 1010,” press 1010 on the numeric keypad.
place the calibration weight on the platter. Press ZERO to calibrate. Once the stable indicator light is displayed, press the ZERO key again. The second line of display will now show 00000. Calibration is now complete. NOTE: The ideal calibration test weight is between 2/3 capacity to full capacity in order to get the most accurate weight after calibration. Turn off the power, then turn it back on again. Place a weight on the platter to ensure weighing is correct. If not, repeat the above steps.
7 Maintenance and service The weighing machine must be treated carefully and cleaned regularly. It is a precision instrument. For maintenance-work, the machine must be separated from the power supply (remove power adapter plug from socket). Also ensure that the weighing machine cannot be reconnected to the power supply during any work by a third party. Take care during cleaning that no liquid penetrates into the weighing machine.
Take care that there are no marked temperature fluctuations during the transportation and that the weighing machine does not become damp (condensation). 8.2 Storage If you would like to take the weighing machine out of service for an extended period, disconnect it from the electricity supply, clean it thoroughly (see Section 6.Maintenance and servicing.