Manual

22
5 Operation
5.1 Tare
5.1.1 Clearing the tare weight
- Place the empty container on the platter. Press the TARE key. The
display will show 0.00000.
- When the container is removed from the platter, the WEIGHT display will
show a minus (-) weight value which is the weight of the container.
5.1.2 Clearing the previous tare weight
- Remove weight from the platter and then press the TARE key. The Tare
indicator will turn off and the WEIGHT display will return to Zero.
5.2 Sample setting
5.2.1 Number setting (for counting any unknown weight)
- Place the pre-counted X number of sample pieces on the platter. The
total weight will be displayed. Set the X number of pieces using the
numeric keys and then press the SAMPLE/UNIT key.
- UNIT WEIGHT on the display shows the average piece weight of the
samples.
- TOTAL (pcs) on the display shows the number of sample pieces on the
scale. Add in more units and it will show the total number of pieces.
5.2.2 Unit weight setting (when unit weight is known)
- Place samples on the scale. Using the numeric keypad, key in the
average piece weight. Press UNIT WEIGHT on the keypad to save the
specified piece weight.
- The total number of pieces will be shown on the TOTAL (pcs). Add in
more units to be counted. Press the CE key to clear previous setting.