Instruction Manual

22
- Remove the weight from the platter then press the
TARE key so that the TARE indicator will turn off and
the WEIGHT display returns to Zero.
5.2 Sample setting (there are two sample
setting methods)
5.2.1 Number setting: (when counting any
unknown weight)
- Place the pre-counted “X” number of samples on the
platter. The total weight will be displayed. Set the “X”
number of samples by using the numeric keys and then
press the SAMPLE/UNIT key.
- UNIT WEIGHT on the display shows the average piece
weight of the sample.
- TOTAL (pcs) on display will show the number of pieces
included in the sample, place more pieces on the platter
to be added to the total sample count.
5.2.2 Unit weight setting: (when unit weight
is known)
- Place samples on the platter. Using the numeric keypad,
key in the average piece weight. Press the UNIT
WEIGHT key on the keypad.
-TOTAL (pcs) on the display will show the total number of
pieces. Add on more pieces to be counted.