5.3 Connecting LXNAV FlarmView
FlarmView can be connected to any Flarm or ADS-B device with FlarmView cable.
5.4 Installation of options
Optionally more FlarmView devices can be connected through FlarmSplitter.
5.4.1 Ports and Wiring
5.4.1.1 LXNAV FlarmView port (RJ11)
1 2 3 4 5 6
Pin numbers
Pin number Description
1 (Power input) 12VDC (On version 2)
2 (Power input) 3.3VDC (On version 1)
3 GND
4 (input) Data in RS232 – receive line
5 (output) Data out RS232 – transmit line
6 Ground
5.4.1.2 LXNAV FlarmView wiring
1
2
3
4
5
6
J1
RJ12
1
2
3
4
5
6
J2
RJ12