Operation Manual

LX90xx system Version 4.0 February 2014
Page 145 of 151
Select Port2 tab and change Baud rate to 19200bps.
The LX90xx system and TRX-1090 are now ready for operation. On the info page you
should see the TX sign and number of received objects.
11.3.1.2 Connecting TRX-1090 to the system
Disconnect cable from the Flarm external display and connect the free cable to Port4 on the
TRX-1090. Use the LX9000-TRX cable (not-included, must be ordered separately) and
connect it between PORT2 and PC port on the main display unit.
On the main display unit go to the setup menu and choose Hardware->Flarm menu item.
Change mode to Ext.(PC).
Port on LX9000 Cable Port on TRX 1090
LX9000 FLARM -> via cable (Flarm-TRX1090) -> TRX Port4
LX9000PC <- via cable (TRX LX9000) <- TRX Port2
11.4 External Flarm or Power Flarm
If main display unit has no internal Flarm, user has a possibility to connect to it external
Flarm or Power Flarm. All Flarm/Power Flarm items will be displayed on the navigation map,
with same functionality as is with built-in Flarm.
11.4.1 Installation
External Flarm/Power Flarm can be connected to the main display unit with LX5FLARM
cable.