User's Manual

Table Of Contents
Resetting the Reader
5-4 Configuration and Operation
using Group S parameters. You can change the settings for the PC or Reader so
that the settings match each other. If you modify the Reader’s parameters, you
must save them before leaving the learning mode. For more information on this
procedure, see Storing the Reader’s Configuration on page 5-13.
6. Press the RESET button again to exit from the learning mode.
7. The DATA LED will stop flashing.
Notes 1. The serial communication configuration for an IPC application has the default
values of the Group S parameters. For more information on the Group S
parameters, refer to the 95 Series RFID System Reference Guide.
2. If the noise and interference level on the UHF channel exceeds the carrier
threshold or a Transponder is transmitting information, the DATA LED will start
flashing at a faster rate.
Resetting the Reader
Thereare2waystoresettheReader(seeFigure5-1):
By resetting the hardware
By resetting the software
For a hardware reset, switch off the Reader’s power supply for a least 5 seconds.
For a software reset, you can:
1. Press the RESET button twice.
or
2. Type the following command at the prompt:
:RESET <Enter>
Checking the Readers Basic Parameters
To check basic parameters on the Reader, do the following:
1. Check the software version number by typing:
IVN <Enter>
Theresponseshouldbe:
IVN=CRM95 V_.__, BUILT: __/__/__ __:__:__.
Note You can upgrade the Reader software, if necessary. For more information on
upgrading the software, refer to Appendix D, Reader Software Upgrade Procedure.