User's Manual
Table Of Contents
- 95 Series RFID System User’s Guide
- Table of Contents
- List of Figures
- Preface
- Introduction
- Reader R95 Installation and Connections
- Exciter E95 Installation and Connections
- Power Supply TRM95 Installation and Connection
- Configuration and Operation
- Before You Begin
- General Procedure Rules
- Setting Up the Reader/PC Connection
- Reader’s Power-up Sequence
- Learning Procedure (Optional)
- Resetting the Reader
- Checking the Reader’s Basic Parameters
- Setting Up the Exciter’s Address
- LF Transmitter Output
- Configuring the Reader
- Setting Up the Carrier Threshold
- Setting Up the Exciter’s Test-Tag
- Setting Up the Real Time Clock
- Configuring the Reader’s Application Parameters
- Configuring the Reader’s Network Parameters
- Storing the Reader’s Configuration
- Reader - Final Setup
- 95 Series RFID System - Final Test
- Programming and Testing the Transponder T95
- Troubleshooting
- Specifications
- Transponder T95 Messages
- Excitation Modes
- Reader Software Upgrade Procedure
- Glossary
- Index
Resetting the Reader
5-4 Configuration and Operation
using Group S parameters. You can change the settings for the PC or Reader so
that the settings match each other. If you modify the Reader’s parameters, you
must save them before leaving the learning mode. For more information on this
procedure, see Storing the Reader’s Configuration on page 5-13.
6. Press the RESET button again to exit from the learning mode.
7. The DATA LED will stop flashing.
Notes 1. The serial communication configuration for an IPC application has the default
values of the Group S parameters. For more information on the Group S
parameters, refer to the 95 Series RFID System Reference Guide.
2. If the noise and interference level on the UHF channel exceeds the carrier
threshold or a Transponder is transmitting information, the DATA LED will start
flashing at a faster rate.
Resetting the Reader
Thereare2waystoresettheReader(seeFigure5-1):
• By resetting the hardware
• By resetting the software
For a hardware reset, switch off the Reader’s power supply for a least 5 seconds.
For a software reset, you can:
1. Press the RESET button twice.
or
2. Type the following command at the prompt:
:RESET <Enter>
Checking the Reader’s Basic Parameters
To check basic parameters on the Reader, do the following:
1. Check the software version number by typing:
IVN <Enter>
Theresponseshouldbe:
IVN=CRM95 V_.__, BUILT: __/__/__ __:__:__.
Note You can upgrade the Reader software, if necessary. For more information on
upgrading the software, refer to Appendix D, Reader Software Upgrade Procedure.