Setting Up the Exciter’s Address
Configuration and Operation 5-5
2. Check the System Code (SC), by typing:
ISC <Enter>
Theresponseshouldbe:
ISC= [your SC]
If the displayed System Code is not identical with the application system code
number, replace the Reader and report the problem to Lyngsoe.
3. Check the Receiver’s Serial Number (SN), by typing:
ISN [your SN]<Enter>
If the displayed serial number is not equal to the serial number on the Receiver’s
CRM95 board, set it to the correct value. For example, if the SN is U123456, then
type:
ISN=U123456<Enter>
4. Store the new SN and/or SC parameter values, by typing:
:CONFIG:STORE <Enter>
:RESET <Enter>
5. Check the correct values of the IVN, ISC,andISN parameters, by repeating
Steps 1 to 3.
6. Switch off the LF field, by typing:
C<Enter>
SettingUptheExcitersAddress
Your next step is to setup an address for each Exciter by using the S1 slide switch on
the EXT95SC board, as shown in Figure 5-2 below.