Setting Up the Real Time Clock
5-12 Configuration and Operation
received, verify whether the UHF channel is jammed or replace the EXT95SC
board.
Note If you do not see the expected number of messages on your PC, (13-15 messages for an
IPC site), see Chapter 7, Troubleshooting and check the following parameters:
DAR=Y; DCI=0, DRI=0
6. Repeat Steps 1 to 5 for each Exciter that is connected to the Reader.
SettingUptheRealTimeClock
You can set the Reader’s date and time by using the IUT parameter. For more
information on setting up the Real Time Clock, refer to the 95 Series RFID System
Reference Guide.
Example For an IPC application, you should set the IUT parameter to GMT time. To set it, type:
IUT=YYMMDDhhmmZ<Enter>
where YYMMDDhhmm is the year, month, day, hour, and minute respectively.
Configuring the Readers Application Parameters
You can configure the Reader’s application parameters by setting the appropriate
values for the parameters in the following groups:
Data buffering/reporting configuration (D)
Hardware configuration (H)
Instrument generic configuration (I)
Tag data reading/excitation configuration (R)
Serial communication configuration (S)
For example, for an IPC application, do the following:
1. Set the data filtration on the Reader, by typing:
DCI=10 <Enter>
DRI=30 <Enter>
2. Set the reported data format as ANS.1 format, by typing:
DHX=Y <Enter>
3. Set the Tag data character count, by typing:
RCC=5 <Enter>
4. Leave the default values for the other parameters.