User's Manual

Table Of Contents
95 Series RFID System - Final Test
5-16 Configuration and Operation
e) Check the received messages, by typing:
@r D<Enter>
or
@r :DATA:REPORT<Enter>
The Reader must respond with the oldest record sent by the Exciter k’s Test-Tag,
in the format set by the DHX parameter. For more information on this parameter,
refer to the 95 Series RFID System Reference Guide.
Note For an IPC application, the Reader’s Tag Record Buffer contains 13-15 identical
messages sent by the Exciter k’s Test Tag in ANS.1 format. To read all messages, you
have to repeat the commands:
@r D<Enter>
@r E<Enter>
until you get the Null value $0500.
f) Empty the Reader’s Tag record buffer, by typing:
@r :DATA:PURGE<Enter>
g) Confirm that the Reader’s buffer is empty, by typing:
@r D<Enter> or @r :DATA:REPORT<Enter>
The Reader must report the Null value ($0500) in ANS.1 format.
4. Repeat Step 3 for all Exciters controlled by the Reader r.
5. Repeat Steps 1 to 4 for all Readers that are connected to the same PC.