User's Manual

Table Of Contents
General Guidelines
Troubleshooting 7-7
Time-out error.
(At the command
:TEST:EXCITER k,the
response is 00,butthe
Main PC does not
receive a message, or a
correct message from
the Test Tag of the
Exciter k after a
predetermined period
of time).
DATA LED is
flickering, the
Reader’s Tag
Record Buffer
contains messages
from the Test Tag.
DATA LED is
flickering, but the
Reader’s Tag
Record Buffer is
empty.
DATA LED is not
flickering
Test tag was incorrectly
programmed.
Test tag was incorrectly
programmed.
Exciter’s Test Tag is
placed beyond the limits
of the receiving zone, or
there is a random
interference on the UHF
channel, or the Test Tag
is out of specifications.
range. When using multiple
Transponders, some messages are lost
due to the inherent collision between
them.
1. Query the Test Tag programming
parameters using
:TAG:QUERY:EXCITER k.
2. Check the value of all group T
parameters.
3. Correct the values using the group
W parameters.
4. Reprogram the Test TAg using the
command :TAG:MATCH:EXCITER k.
1. Query the Test Tag programming
parameters using
:TAG:QUERY:EXCITER k.
2. Check the value of all group T
parameters.
3. Correct the values using the group
W parameters.
4. Reprogram the Test Tag using the
command :TAG:MATCH:EXCITER k.
1. Run the procedure, 95 Series RFID
System - Final Test on page 5-14.
Step 2 - Set up the Carrier
Threshold for the Reader.
2. Check the RF level of the messages
received from the Test Tag; it must
be higher than (RSS+HNL+3)dBm,
that means 3dB above the carrier
threshold value.
Note
The Reader reports the RF level of the
received message only if the parameter
DLI=Y.
3. If the RF level of the Test Tag’s
received messages is lower than
-85dBm, either reposition the
Reader or Exciter, or use a higher
gain UHF antenna for the Reader.
Problem Symptom Probable Cause Solution