Specifications A-3
Additional
Features
RF antenna diversity.
RF input signal level measurement. This information is attached to every received
message.
Programmable carrier threshold. Only input RF signals above this threshold are
processed.
Real time clock: a time stamp (Month/Day/Hour/Minute) can be added to every
received message.
Reads data with or without error checking and encryption in hexadecimal or
ASCII format.
Received messages can be filtrated by time, RF signal level, system code, and data
content.
Stores over 50 kbytes of received messages in an internal buffer.
Interfaces with a PC through the RS-232 or RS-485 interface. The RS-485 can be
configured for half-duplex (2 wires) or full-duplex (4 wires).
Controls up to 15 Exciters E95 through a dedicated RS-485 interface.
Reader’s firmware can be upgraded using the serial interface.
Power Supply 12Vac ±10%, 50/60 Hz, or 13 to 16 Vdc.
Power
Consumption
Maximum 0.3 A.
Environmental
Operation
Temperature
-20°Cto+55°C.
Storage
Temperature
-40°Cto+70°C.
Relative
Humidity
Maximum95%,non-condensingat+40°C.
Mechanical Dimensions (without UHF antennas)
Length: 250 ± 5 mm
Width: 210 ± 5 mm
Height: 100 ± 5 mm
•Weight:max4kg
Approvals Approved under I-ETS 300-220, I-ETS 300-330, RS-210 and FCC Part 15.