User's Manual
Table Of Contents
- 95 Series RFID System User’s Guide
- Table of Contents
- List of Figures
- Preface
- Introduction
- Reader R95 Installation and Connections
- Exciter E95 Installation and Connections
- Power Supply TRM95 Installation and Connection
- Configuration and Operation
- Before You Begin
- General Procedure Rules
- Setting Up the Reader/PC Connection
- Reader’s Power-up Sequence
- Learning Procedure (Optional)
- Resetting the Reader
- Checking the Reader’s Basic Parameters
- Setting Up the Exciter’s Address
- LF Transmitter Output
- Configuring the Reader
- Setting Up the Carrier Threshold
- Setting Up the Exciter’s Test-Tag
- Setting Up the Real Time Clock
- Configuring the Reader’s Application Parameters
- Configuring the Reader’s Network Parameters
- Storing the Reader’s Configuration
- Reader - Final Setup
- 95 Series RFID System - Final Test
- Programming and Testing the Transponder T95
- Troubleshooting
- Specifications
- Transponder T95 Messages
- Excitation Modes
- Reader Software Upgrade Procedure
- Glossary
- Index
Reader R95
Specifications A-3
Additional
Features
• RF antenna diversity.
• RF input signal level measurement. This information is attached to every received
message.
• Programmable carrier threshold. Only input RF signals above this threshold are
processed.
• Real time clock: a time stamp (Month/Day/Hour/Minute) can be added to every
received message.
• Reads data with or without error checking and encryption in hexadecimal or
ASCII format.
• Received messages can be filtrated by time, RF signal level, system code, and data
content.
• Stores over 50 kbytes of received messages in an internal buffer.
• Interfaces with a PC through the RS-232 or RS-485 interface. The RS-485 can be
configured for half-duplex (2 wires) or full-duplex (4 wires).
• Controls up to 15 Exciters E95 through a dedicated RS-485 interface.
• Reader’s firmware can be upgraded using the serial interface.
Power Supply 12Vac ±10%, 50/60 Hz, or 13 to 16 Vdc.
Power
Consumption
Maximum 0.3 A.
Environmental
Operation
Temperature
-20°Cto+55°C.
Storage
Temperature
-40°Cto+70°C.
Relative
Humidity
Maximum95%,non-condensingat+40°C.
Mechanical • Dimensions (without UHF antennas)
Length: 250 ± 5 mm
Width: 210 ± 5 mm
Height: 100 ± 5 mm
•Weight:max4kg
Approvals Approved under I-ETS 300-220, I-ETS 300-330, RS-210 and FCC Part 15.