User's Manual
Table Of Contents
- 95 Series RFID System User’s Guide
- Table of Contents
- List of Figures
- Preface
- Introduction
- Reader R95 Installation and Connections
- Exciter E95 Installation and Connections
- Power Supply TRM95 Installation and Connection
- Configuration and Operation
- Before You Begin
- General Procedure Rules
- Setting Up the Reader/PC Connection
- Reader’s Power-up Sequence
- Learning Procedure (Optional)
- Resetting the Reader
- Checking the Reader’s Basic Parameters
- Setting Up the Exciter’s Address
- LF Transmitter Output
- Configuring the Reader
- Setting Up the Carrier Threshold
- Setting Up the Exciter’s Test-Tag
- Setting Up the Real Time Clock
- Configuring the Reader’s Application Parameters
- Configuring the Reader’s Network Parameters
- Storing the Reader’s Configuration
- Reader - Final Setup
- 95 Series RFID System - Final Test
- Programming and Testing the Transponder T95
- Troubleshooting
- Specifications
- Transponder T95 Messages
- Excitation Modes
- Reader Software Upgrade Procedure
- Glossary
- Index
Exciter E95
A-4 Specifications
Exciter E95
LF Transmitter • Carrier Frequency: 125.0 kHz, quartz crystal generated.
• Modulation type: On/Off Keying (OOK).
• Modulation Frequency: 600 ±10 Hz.
• Carrier and modulation frequency tolerance: ± 50 ppm (± 6.6 kHz).
• Carrier and modulation frequency stability: better than 100 ppm (± 13.2 kHz) over
the temperature range.
• Carrier and modulation frequency aging: maximum 3 ppm/year (0.4 Hz/year).
• Maximum radiated E-field at 10 m: 105 ±6 dB µV/m.
Additional
Features
• Exciter E95 incorporates a UHF transmitter that simulates the Transponder T95
to check the Reader’s capability.
• Test Transponder can be programmed and activated from the main PC.
• Self diagnostic for LF-Transmitter output level.
• Self diagnostic for power supply voltage level.
• Output relay driving
• Input Object Sensor
Power Supply 22 Vac ±10%, 50/60 Hz; or 23 - 28 Vdc.
Power
Consumption
Maximum 0.5 A.
Environmental
Operation
Temperature
- 20°C to +55°C.
Storage
Temperature
- 40°C to +70°C.
Relative
Humidity
Maximum 95%, non-condensing at +40°C.
Mechanical • Dimensions
Length: 2060 ± 10 mm
Width: 1000 ± 10 mm
Height: 75 ± 5 mm
• Weight: max 5.5 kg