User's Manual

Table Of Contents
Exciter E95
A-4 Specifications
Exciter E95
LF Transmitter Carrier Frequency: 125.0 kHz, quartz crystal generated.
Modulation type: On/Off Keying (OOK).
Modulation Frequency: 600 ±10 Hz.
Carrier and modulation frequency tolerance: ± 50 ppm 6.6 kHz).
Carrier and modulation frequency stability: better than 100 ppm (± 13.2 kHz) over
the temperature range.
Carrier and modulation frequency aging: maximum 3 ppm/year (0.4 Hz/year).
Maximum radiated E-field at 10 m: 105 ±6 dB µV/m.
Additional
Features
Exciter E95 incorporates a UHF transmitter that simulates the Transponder T95
to check the Reader’s capability.
Test Transponder can be programmed and activated from the main PC.
Self diagnostic for LF-Transmitter output level.
Self diagnostic for power supply voltage level.
Output relay driving
Input Object Sensor
Power Supply 22 Vac ±10%, 50/60 Hz; or 23 - 28 Vdc.
Power
Consumption
Maximum 0.5 A.
Environmental
Operation
Temperature
- 20°C to +55°C.
Storage
Temperature
- 40°C to +70°C.
Relative
Humidity
Maximum 95%, non-condensing at +40°C.
Mechanical Dimensions
Length: 2060 ± 10 mm
Width: 1000 ± 10 mm
Height: 75 ± 5 mm
Weight: max 5.5 kg