User's Manual

Table Of Contents
System Performance
A-6 Specifications
Readers can simultaneously identify up to 15 Transponders present in the excitation
field. The level of accuracy is greater than 95%.
System Capacity Up to 31 Readers R95 can be connected through the RS-485 interface to the main PC.
Up to 15 Exciters E95 can be controlled by any Reader R95. More Exciters E95 can be
used to generate a specific shape for the excitation gate.
Self Testing
Capabilities
At the request of the main computer, the RFID System automatically reports the
status of the LF excitation field generated by each Exciter E95, and the receiving
capability of each Reader R95.
Object Sensor
Monitoring
An external object sensor device can switch the excitation field On and Off.
Driving Output A Single Pole Double Throw (SPDT) relay contact is available to drive external
devices. The relay is activated each time the Reader receives a correct message.