User's Manual

Upgrading the Firmware
Reader Software Upgrade Procedure D-1
Appendix D
Reader Software Upgrade Procedure
This appendix describes the procedures for upgrading the Reader RD21 (P/N 600002) main
software using the serial interface RS232 or RS485. This software controls the functionality of the
Micro controller placed on the Receiver assembly REC21 (P/N 500007).
Upgrading the Firmware
Upgrading the firmware involve the following steps:
1. Setting the Reader’s Address to 0
2. Saving parameters (those that are different from default)
3. Upgrading the firmware itself by using:
a) The RS232 interface
or
b) The RS485 interface: 4-wire communication line or 2-wire communication line
3. Restoring parameters
4. Setting the Reader’s Network Configuration
5. Final instructions
Setting the Readers
Address
To set the Readers address, do the following:
1. If the Reader already has an address, for example r, then set this address to 0 by typing the
following commands:
@r IAD=0<Enter>
@r :CONFIG:STORE<Enter>
@r :RESET<Enter>
For more information, refer to Storing the Readers Configuration on page 5-17.
2. Check whether the Reader’s address is 0, by typing the following command:
IVN<Enter>
The Reader must respond with its software version number. If not, repeat Step 1.