5.5.1. Receiver commands
Querying Firmware version in the 434MHz receiver (RD23):
@1 IVN
@1 OK
@1 IVN="RD23_V3.1.02, BUILT: May 19 2009 at 09:56:22"
Reading the first 5 tag records stored in the RD23:
@1 :Y 5
@1 {TS="0406151824Z",LI=-83,UD="\x11"3DU",EX="\xFF",CT="Z",FG="HI"}
@1 {TS="0406151824Z",LI=-71,UD="TR030",EX="\xFF",CT="Z",FG="HI"}
@1 {TS="0406151824Z",LI=-78,UD="TR036",EX="\xFF",CT="Z",FG="HI"}
@1 {TS="0406151824Z",LI=-72,UD="TR030",EX="\xFF",CT="Z",FG="HI"}
@1 {TS="0406151824Z",LI=-83,UD="C\xFD\x00W\xE0",EX="\xFF",CT="@",FG="HI"}
@1 05 ;Comment: this number varies, here it shows that 5 records were displayed
Finding out the total number of tag records from RD23:
@1 DMC
@1 OK
@1 DMC=163
Erasing all tag records from RD23:
@1 :DATA:PURGE
@1 OK
@1 00
5.5.2. Exciter commands
Querying Firmware version in the 125kHz transmitter – the Exciter EXB40 module:
#1 EVN
#1 EVN=0.2
#1 OK
Turning OFF the 125kHz field (after power up the field is ON):
#1 C
#1 OK