User's Manual
Lyngsoe Systems Combi RFID Master MC30RG
Doc no. 950237 - Page 11 of 14
Turning ON the 125kHz field:
#1 B
#1 OK
5.5.3. Motherboard commands
Querying Firmware version in the motherboard MBD40:
%1 IVN
%1 OK
%1 MBD40 RFID Portal Motherboard v2.0.9 Built 9-Sep-09
Displaying the hex value of a number on the 7-segment displays (from 00-FF). If “B” is specified the display will blink
on and off.
%1 DSP=05 B
%1 OK
%1 DSP=05 ;the display will blink “05”, on and off.
Querying the status of the “Test” or “Send” buttons:
%1 BTS
%1 OK
%1 BTS=Y ; Shows that the Send button was pressed at least once since the last reset. Must be cleared manually
after reading by sending the “BTS=N” command or “:RESET”. Use BTT for the “Test” button.
Disconnecting the power for the active equipment (RD23, EX23) for 10 seconds:
%1 CSD
%1 OK
%1 00 ; waits for 10secs before re-applying power, then replies 00.
Disconnecting the power to the Single Board Computer for 10 seconds:
%1 CPC
%1 OK
%1 00 ; waits for 10secs before re-applying power, then replies 00.
Disconnecting the power to the GSM modem for 10 seconds:
%1 CGS
%1 OK
%1 00 ; waits for 10secs before re-applying power, then replies 00.