Motherboard
MBD40 RevA
UHF Passive
(Impinj Revolution
+ 24Vdc/1A)
LF1
+5V/3.5A
+12V/0.2A
EX23H
(+24V/1A)
RS485 &
+24Vdc/1A
RS485 &
+24Vdc/0.2A
UHF4
UHF3
+24V/0.1A
COMBI RFID MASTER MC30RG (RFID PORTAL LS4230)
– BLOCK DIAGRAM – REV.A MOTHERBOARD
THURSDAY, JANUARY 14, 2010
(J6)
+24Vdc
(passive reader)
(J17)
(J12)
RF Modem
RS485 & +24V
(J13)
GSM Modem
RD23
(3W)
SBC
(13 Watts)
COM1
RS232
COM2
RS232
UHF1 UHF2
LF1 LF2
LF2
(J15)
DC Power
DATA
Data & Power
Legend:
RJ45 - Ethernet Data
RJ45 - Ethernet Data
External RJ45 - Ethernet Data
COM4
RS232
(J9)
(J10) (J11)
DC IN +24V DC OUT +24VRS485 IN RS485 OUT
(J2, J3) (J18, J19)
Figure 5 - Block Diagram
Note: The RF modem is an add-on module that is not available yet as of 15 December 2009.
3. Installation
Typical installation of the MC30RG is presented in Figure 6 below. The MC30RG portal requires one 18
AWG 3 wires power cable to be run to the mid point of the portal (connectors J15 or J16) from a +24V power
supply. It should have an extra 3ft at each end.
Two metal chains will be dropped from the ceiling, 70cm apart. The unit shall be hung from the metal chains
using two S-links connected to the two existing chains attached to the exciter. The exciter weight doesn’t
exceed 18Kg. A Lyngsoe technician will do the final cable connections.