LF Transmitter Output
5-6 Configuration and Operation
The addresses must be sequential between 1 and 14. For example, if there are 4
Exciters, they must be assigned addresses 1, 2, 3, and 4. Use the S1 switch to set the
address to binary format. For example, in binary format:
address 1 is 0001
2
address 2 is 0010
2
address 3 is 0011
2
address 4 is 0100
2
If the switch is in the ON position, the bit is set to 1. Otherwise, the bit is set to 0.
Note Addresses 0000
2
and 1111
2
are reserved for special modes of operation.
LF Transmitter Output
To check the LF signal, refer to Figure 5-3 below, and do the following:
Figure 5-3: LF Signal Measurement
1. Connect the power to the Exciter.
2. Check the current parameter settings for the excitation mode and write down the
value of the following parameters: RCS, RES, REM, RET, HCC, HCS, HE0, and
HE1.
Note To determine the value of a parameter, for example, HE1, type the command:
HE1 <Enter>
Exc iter Slave EXT95SC
TB2
ANT
GND
Black
TAP
Red
White
To LF Antenna
T e rmi na l Blo ck
Oscilloscope