Brochure
SPECIFICATIONS & INSTALLATION
THE SEDONA BY LYNX COLLECTION
BUILT-IN GRILL
Model A B C
L400 23” 10” 21-1/4”
L500 29” 10” 21-1/4”
L600 35” 10” 21-1/4”
L700 41” 10” 21-1/4”
COMPLEMENTARY PRODUCTS
Model A B C
LSB501* 11” 4” 16”
LSB502* 21” 4” 16”
LDR424 22” 19” –
LDR530 28-1/4” 19” –
LDR636 33-3/4” 19” –
LSA530 28-1/4” 19” 20”
LSA636 33-3/4” 19” 20”
LUD517 17-1/4” 12-3/4” 20”
L500REF 21-1/2” 34” 24-1/2”
BUILT-IN GRILL WITH INSULATING JACKET
Model A B C
LIJ400 30” 11-5/8” 23-1/4”
LIJ500 36” 11-5/8” 23-1/4”
LIJ600 42” 11-5/8” 23-1/4”
LIJ700 48” 11-5/8” 23-1/4”
1
1/8
” min. for model LUDE
3
1/2
” min. for model LUDXL
2
1/2
” min. for model LDR (access door)
* Cocktail Pro should have an open bottom for plumbing and drain access.
** 1” square hole must be located at rear of grill cutout. 120V GFI outlet must
be located within 6’ of the 1” hole.
GAS
NON-COMBUSTIBLE
CONSTRUCTION
3”
F
21
3
/4
''
2”Ø or 2” square holes
for manifold connection
(rear or bottom access)
12” min.
Grill**
Cocktail Pro*
Warming Drawer/
Convenience Center
Utility
Drawer
Side
Burner
Access
Doors
19”
A
B
D
E
G
H
29”
2
1/4
”
3
1/2
”
3
1/4
” min.
2”
H
3” min.
C
24”
Trash
Center
36
3/8
”
min.
3
1/2
”
8
1/4
”
6
1/4
”
Trash
Chute
5
5/
8
''
2
3/
16
''
Single
Storage Drawer
16”
3”
min.
14
1/2
''
8
1/4
''
Towel
Dispenser
NON-COMBUSTIBLE
CONSTRUCTION
The guides, measurements and dimensions detailed below are designated to assist you with planning your outdoor kitchen.
NOTE: Due to continuing product innovation, specifications are subject to change without notice. All measurements are in inches.
IMPORTANT: Please reference the Care & Use / Installation manual for details on gas plumbing requirements, electrical specifications and the
proper installation of your Lynx outdoor kitchen equipment. This manual can be downloaded from the Lynx website at www.lynxgrills.com
Note: Insulating jacket required for all grills installed into
a combustible enclosure.
Note: For Natural Gas grills, Lynx recommends using 3/4” gas lines.
Note: Side burners may be rotated 90 degrees.
See installation manuals for details.
COUNTER TOP NOTCH DETAIL
Only required if island counter top overhangs the face of the island
Insulating
Jacket
A
5”
3”
C
B
4-1/2”
A
A
Double
Drawers
(LUD)
Single
& Double
Side Burner
(LSB)
Outdoor
Refrigerator
(L500REF)
CUTOUT NOT
REQUIRED
WITH LIJs
Door & Drawer Options
(LDR, LSA)
1-1/2” min.
C
B
B
A
A
3-1/2”
3-1/2”
12”
2” 34”
2-1/4”
21-1/2”
9/16”
* When installing the LSB side burners
over the refrigerator; the counter top
must be at least 37-1/2” above the floor.
17