Sonoma Smoker By Lynx™ Care & Use P/N 35948 Page 17
GAS CONNECTIONS…(connued)
Always leak test the connecon aer relling or exchanging
liquid propane cylinders. (See INDEX: “Leak Test” for further
details.)
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL GROUNDING
Product installaon must meet local electrical codes, or in the absence of local codes, the latest edion of the Naonal Electrical
Code ANSI/NFPA No. 70 or the Canadian Electrical Code CSA C22.1.
Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
Do not use this outdoor cooking appliance if it has been submerged underwater without a thorough inspecon by a qualied
technician.
This smoker is equipped with a three-prong (grounded) electric plug for your protecon against shock hazard and must be
plugged directly into a properly grounded three-prong outlet. Never cut or remove the grounding prong from this plug.
Use only extension cords with a three-prong grounding plug, rated for the power of the equipment and approved for outdoor use
with a “W-A” marking.
To protect against electric shock, do not immerse any part of the power cord, an extension cord, or any plugs in water or other
liquid.
Unplug the product before thorough cleaning. Allow it to cool before pung on or taking o parts.
Do not let the cord hang over the edge of a table or touch hot surfaces.
Do not use an outdoor cooking gas appliance for purposes other than intended.
Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or aer the appliance malfuncons or has been
damaged in any manner. Contact Lynx for repair.
Gas Line Purging
You should purge the gas line of air before aempng to light the
oven.
Make sure all oven controls are in the “OFF” posion.
Disconnect the line from the manifold. Slowly turn on the
main gas supply.
As soon as you smell gas, shut o the supply
Reconnect the line, and test for leakage.
Turn the supply back on slowly.
Wait at least 5 minutes before aempng to light the burner.
Liquid Propane Connecons
Make sure the liquid propane cylinder valve is completely
closed. It is possible for the valve to be opened without
releasing gas, but as soon as you start connecng the regulator,
gas can ow from the connecon.
Insert the regulator inlet into the cylinder valve and turn the
black coupler clockwise unl the coupler is hand ght. Do not
over-ghten this connecon.
To disconnect the coupler, rst make sure the main cylinder
valve is turned o. Grasp the coupler and turn counter-
clockwise. The inlet will then disengage.
Liquid Propane regulator
for a portable tank
Connects to
portable tank
Connects to
manifold