Manual

12
|
CARE & USE/INSTALLATION
Dégagement horizontal minimal entre les parois
latérales et l’arrière de l’appareil et la construction
verticale combustible au-dessus de l’appareil (45.7
cm à partir des parois latérales et 45.7 cm à partir de
l’arrière).
Do not use this appliance under unprotected overhead
combustible surfaces.
Ne pas utiliser cet appareil en-dessous de surfaces
combustibles non protégées.
If the grill is to be placed into a combustible enclosure,
an approved insulated jacket is necessary and is
available only from Lynx or your Lynx dealer. Lynx
insulated jackets have been designed and tested
specifically for your Grill.
OVERHEAD PROTECTION AND EXHAUST REMOVAL
If the grill is installed under any combustible construction
the cooking area over the grill must be covered with an
outdoor approved exhaust hood. The hood must provide 3
to 6 inches of overhang on all exposed sides. The bottom
of the hood should be positioned at least 36 inches above
the counter top surface. The exhaust hood shall provide no
less than 1200 CFM for proper exhaust ventilation and it
must be provided with a dedicated GFCI protected branch
circuit.
REAR HOOD CLEARANCE
A 3 inch clearance is required behind the grill to provide
unobstructed opening of the hood.
The grill exhausts combustion products and cooking
greases to the back. Never locate the grill where this
exhaust will be difficult to clean.
SPECIFICATIONS AND INSTALLATION
The guides, measurements and dimensions detailed below
are designed to assist you with planning your outdoor
kitchen.
NOTE: Due to continuing product innovation, specifications
are subject to change without notice.
IMPORTANT: Please reference the Care & Use/Installation
manual for details on gas plumbing requirements,
electrical specifications and the proper installation of your
Lynx outdoor kitchen equipment. This manual can be
downloaded from the Lynx Web site at www.lynxgrills.com.
IMPORTANT INSTALLATION NOTES
HOW LONG IS YOUR RUN?
Keep all gas supply lines as short as possible. Gas lines lose
pressure over distance and with each elbow and tee that is
added. This drop in pressure affects the grill’s performance.
(See INDEX: “Gas Supply Line Runs” for further details.)
BE SURE YOUR GRILL IS LEVEL
Proper levelling during installation is critical to the smooth
operation of your SmartGrill by Lynx™. A grill that is out of
level will cause erratic burner combustion and inefficient,
uneven heating. A carpenter’s spirit level should be used to
level the grill both front-to-back and side-to-side.
If the floor is uneven or has a pronounced slope, re-leveling
may be required each time you move a freestanding
SmartGrill by Lynx™.
BEFORE YOU START...(continued)