Manual

32
|
CARE & USE/INSTALLATION
TROUBLESHOOTING ...continued
Is the cylinder almost empty?
Almost empty cylinders may not have sufficient pressure to
run the burners at high heat.
Have the line pressure checked by a qualified technician.
Flow limiting device.
Improper lighting procedure may have activated the liquid
propane cylinder’s flow control device, reducing heat
output.
To reset the flow control:
Shut off all burner controls and close the liquid propane
cylinder valve.
Open one gas valve to relieve any pressure in the LP
hose, then close the gas valve
Wait 30 seconds and, very slowly, reopen the cylinder
valve.
Wait a few seconds and relight a burner.
Bulk Liquid Propane cylinder users:
Bulk liquid propane cylinder lines must be properly
regulated.
Ensure that you are using a 4/11 appliance regulator
supplied by Lynx and converted to liquid propane gas.
Also, ensure that you do not have more than one regulator
in line.
Natural Gas Units:
Supply line
Ensure that the supply line is at least ¾” inside diameter or
1” outside diameter.
Check Line pressure
Natural gas inlet pressure should be at least 5” W.C. and
manifold pressure not less than 4” W.C. under full load
(with all burners on).
Check burners for blockages.
LOW OR INSUFFICIENT HEAT
Proper levelling during installation is critical. A grill that
is out of level will cause erratic burner combustion and
inefficient, uneven heating. A carpenter’s spirit level should
be used to level the grill both front-to-back and side-to-
side.
If the low heat problem persists:
Check the gas supply line sizing requirements.
Check the gas supply line for kinks or damage.
Check the thermostatic control for proper operation.
LIGHTS WON’T LIGHT
For the blue LED lights and white halogen lights
Check power
Ensure that the grill is connected to a live AC power
source.
SMARTGRILL SELF-DIAGNOSIS
Your SmartGrill by Lynx technology includes self-
diagnosis of some issues and will let you know either
with an audible statement of the issue, or send you a text
message displayed in your app. "Burner <N>" indicates
the SmartGrill will tell you if it is Burner 1, 2, 3, or the Top
Burner (rotisserie). Any time a burner does not light, the
SmartGrill will turn that burner off.
Audible: "Burner <N> igniter malfunctioned."
Text: "Igniter failed to start."
Indicates the igniter has a problem. Check to see if gas is
turned on. Wait 5 minutes for the gas to dissipate, then try
lighting it again. Call Lynx at 888-289-5969.
Audible: "Burner <N> ignition malfunction."
Text: "Burner <N> failed to ignite ."
Indicates the burner is not lit. Check to see if gas is turned
on. Wait 5 minutes for the gas to dissipate, then try lighting
it again. If it still does not light, call Lynx at 888-289-5969.
Audible: "Burner <N> could not stabilize."
Text: "Burner <N> failed to stabilize.
The burner was set a little too cool. Wait 5 minutes for the
gas to dissipate, then light it again. Leave it on high for a
little longer to heat up before adjusting it down to your
target temperature.
Audible: "Burner <N> cannot reach target temperature."
Text: "Burner <N> cannot reach target temperature."
Check to see if gas is turned on. Wait 5 minutes for the
gas to dissipate, then try lighting it again. If it still does not
light, call Lynx at 888-289-5969.
Audible: "Burner <N> has no flame."
Text: "Burner <N> has no flame."