User Manual
8BConfiguring Multiple AES16’s 
9.4  Mixer settings 
With the clock connections in place, the sample 
clock settings of each AES16 must be adjusted 
using the Lynx Mixer. 
For the master AES16: 
¾  Select the master AES16 Adapter window of 
the Lynx Mixer. 
¾  Select a desired Sample Clock Source. 
¾  Select a desired Sample Clock Reference. 
For each slave AES16: 
¾  Select the master AES16 Adapter window of 
the Lynx Mixer. 
¾  Set the Sample Clock Source to Header if 
internal clock connections are used or 
External if external clock connections are 
used. 
¾  Set the Sample Clock Reference to Word. 
AES16 User Manual  70